Follow
Christopher R Dennison, PhD PEng
Christopher R Dennison, PhD PEng
Verified email at uvic.ca
Title
Cited by
Cited by
Year
Bicycle helmets are highly effective at preventing head injury during head impact: Head-form accelerations and injury criteria for helmeted and unhelmeted impacts
PA Cripton, DM Dressler, CA Stuart, CR Dennison, D Richards
Accident Analysis & Prevention 70, 1-7, 2014
1922014
A qualitative review of sports concussion education: prime time for evidence-based knowledge translation
M Mrazik, CR Dennison, BL Brooks, KO Yeates, S Babul, D Naidu
British journal of sports medicine 49 (24), 1548-1553, 2015
1202015
Ex vivo measurement of lumbar intervertebral disc pressure using fibre-Bragg gratings
CR Dennison, PM Wild, PWG Byrnes, A Saari, E Itshayek, DC Wilson, ...
Journal of biomechanics 41 (1), 221-225, 2008
672008
A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements
CR Dennison, PM Wild, DR Wilson, PA Cripton
Measurement Science and Technology 19 (8), 085201, 2008
612008
An in-fiber Bragg grating sensor for contact force and stress measurements in articular joints
CR Dennison, PM Wild, DR Wilson, MK Gilbart
Measurement Science and Technology 21 (11), 115803, 2010
502010
Predicting Cumulative and Maximum Brain Strain Measures From HybridIII Head Kinematics: A Combined Laboratory Study and Post-Hoc Regression Analysis
BM Knowles, CR Dennison
Annals of biomedical engineering 45, 2146-2158, 2017
472017
Enhanced sensitivity of an in-fibre Bragg grating pressure sensor achieved through fibre diameter reduction
CR Dennison, PM Wild
Measurement Science and Technology 19 (12), 125301, 2008
462008
Mechanisms of cervical spine injury in rugby union: is it premature to abandon hyperflexion as the main mechanism underpinning injury?
CR Dennison, EM Macri, PA Cripton
British journal of sports medicine 46 (8), 545-549, 2012
402012
Validation of a Novel Minimally Invasive Intervertebral Disc Pressure Sensor Utilizing In-Fiber Bragg Gratings in a Porcine Model: An: Ex Vivo: Study
CR Dennison, PM Wild, MF Dvorak, DR Wilson, PA Cripton
Spine 33 (17), E589-E594, 2008
392008
Mechanically stable intraspinal microstimulation implants for human translation
A Toossi, DG Everaert, A Azar, CR Dennison, VK Mushahwar
Annals of biomedical engineering 45, 681-694, 2017
262017
Compressive follower load influences cervical spine kinematics and kinetics during simulated head-first impact in an in vitro model
A Saari, CR Dennison, Q Zhu, TS Nelson, P Morley, TR Oxland, ...
Journal of biomechanical engineering 135 (11), 111003, 2013
262013
Effects of external helmet accessories on biomechanical measures of head injury risk: An ATD study using the HYBRIDIII headform
RC Butz, BM Knowles, JA Newman, CR Dennison
Journal of biomechanics 48 (14), 3816-3824, 2015
242015
A distributed pressure measurement system comprising multiplexed in-fibre Bragg gratings within a flexible superstructure
DA Singlehurst, CR Dennison, PM Wild
Journal of lightwave technology 30 (1), 123-129, 2011
212011
A test bed to examine helmet fit and retention and biomechanical measures of head and neck injury in simulated impact
YY Henry, BM Knowles, CR Dennison
JoVE (Journal of Visualized Experiments), e56288, 2017
202017
Stress Measurements on the Articular Cartilage Surface Using Fiber Optic Technology and In-Vivo Gait Kinematics
P Vakiel, M Shekarforoush, CR Dennison, M Scott, CB Frank, DA Hart, ...
Annals of Biomedical Engineering 48, 2836-2845, 2020
192020
High rate compressive behaviour of a dilatant polymeric foam
KB Bhagavathula, A Azar, S Ouellet, S Satapathy, CR Dennison, ...
Journal of Dynamic Behavior of Materials 4, 573-585, 2018
182018
Superstructured fiber-optic contact force sensor with minimal cosensitivity to temperature and axial strain
CR Dennison, PM Wild
Applied optics 51 (9), 1188-1197, 2012
182012
Sensitivity of Bragg gratings in birefringent optical fiber to transverse compression between conforming materials
CR Dennison, PM Wild
Applied Optics 49 (12), 2250-2261, 2010
172010
Repeatability of strain magnitude and strain rate measurements in the periodontal ligament using fibre Bragg gratings: An ex vivo study in a swine model
DL Romanyk, R Guan, PW Major, CR Dennison
Journal of Biomechanics 54, 117-122, 2017
152017
Multi-point pressure sensor and uses thereof
PM Wild, CR Dennison, DA Singlehurst, C Bueley
US Patent 8,805,128, 2014
152014
The system can't perform the operation now. Try again later.