Analysis of the effect of cone-beam geometry and test object configuration on the measurement accuracy of a computed tomography scanner used for dimensional measurement J Kumar, A Attridge, PKC Wood, MA Williams Measurement Science and Technology 22 (3), 035105, 2011 | 86 | 2011 |
A new approach for filtering of surface profiles using morphological operations J Kumar, MS Shunmugam International Journal of Machine Tools and Manufacture 46 (3-4), 260-270, 2006 | 44 | 2006 |
Fitting of robust reference surface based on least absolute deviations J Kumar, MS Shunmugam Precision engineering 31 (2), 102-113, 2007 | 22 | 2007 |
Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography J Kumar, D Landheer, J Barnes-Warden, P Fenne, A Attridge, ... Forensic science international 214 (1-3), 48-58, 2012 | 17 | 2012 |
Effect of X-ray computed tomography scanning parameters on the estimated porosity of foam specimens J Kumar, AHG Abulrub, A Attridge, MA Williams Applied Mechanics and Materials 110, 808-815, 2012 | 13 | 2012 |
Morphological operations on engineering surfaces using a 3D-structuring element of an appropriate size J Kumar, MS Shunmugam Measurement Science and Technology 17 (10), 2655, 2006 | 10 | 2006 |
Fitting of three-dimensional reference surfaces for engineering surfaces by non-linear least squares J Kumar, MS Shunmugam Journal of computing and information science in engineering 6 (4), 349-354, 2006 | 7* | 2006 |
Three-dimensional characterization of engineering surfaces using triangular motifs J Kumar, MS Shunmugam Proceedings of the Institution of Mechanical Engineers, Part C: Journal of …, 2005 | 5 | 2005 |
Fitting of a robust reference profile for separation of form and waviness from surface profiles J Kumar, MS Shunmugam Thirty-Fourth North American Manufacturing Research Conference 34, 523-530, 2006 | 3* | 2006 |
Virtual reality for visualisation of complex macrostructure AHG Abulrub, J Kumar, A Attridge, KK Mallick, MA Williams 2011 IEEE International Symposium on VR Innovation, 19-23, 2011 | 2 | 2011 |
High resolution industrial grade CT validation of a novel method to locate the mid bundle bifurcate ridge position for the femoral tunnel in ACL reconstruction J Bird, MA Williams, J Kumar, M Carmont, M Dhillon, C Brown, T Spalding | | 2011 |
Effectiveness of Fractal Methods in Characterizing Surface Profiles I Priyavarshini, J Kumar, MS Shunmugam Proc. of COPEN-2005, Jadhavpur University, Kolkata India, 419-423, 2005 | | 2005 |
Comparison of Motif, Morphological and Envelope Filters used for Surface Profile Filtering K Jagadeesha, MS Shunmugam Proc. of COPEN 2005, Jadhavpur University Kolkata India, 412-418, 2005 | | 2005 |
COMPUTATION OF LEAST SQUARES REFERENCE PROFILE FOR SURFACE ROUGHNESS ASSESSMENT J Kumar, MS Shunmugam Innovating the Future Through Manufacturing, 337, 2005 | | 2005 |