Pedro Andreo
Pedro Andreo
Professor of Medical Radiation Physics, Karolinska Institute
Verified email at ki.se
Title
Cited by
Cited by
Year
Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standard of Absorbed Dose to Water
International Atomic Energy Agency. World Health Organization. Pan American ...
International Atomic Energy Agency, 2000
9552000
Monte Carlo techniques in medical radiation physics
P Andreo
Physics in Medicine and Biology 36, 861-920, 1991
8241991
A new formalism for reference dosimetry of small and nonstandard fields
R Alfonso, P Andreo, R Capote, MS Huq, W Kilby, P Kjšll, TR Mackie, ...
Medical physics 35 (11), 5179-5186, 2008
6222008
Handbook of radiotherapy physics: theory and practice
P Mayles, A Nahum, JC Rosenwald
CRC Press, 2007
6122007
Nature and empire: science and the colonial enterprise
RM MacLeod
University of Chicago Press, 2000
546*2000
Calculation and application of point spread functions for treatment planning with high energy photon beams
A AhnesjŲ, P Andreo, A Brahme
Acta Oncologica 26 (1), 49-56, 1987
2461987
Positron flight in human tissues and its influence on PET image spatial resolution
A Sanchez-Crespo, P Andreo, SA Larsson
European journal of nuclear medicine and molecular imaging 31 (1), 44-51, 2004
2302004
The IAEA/WHO TLD postal programme for radiotherapy hospitals
J Izewska, P Andreo
Radiotherapy and oncology 54 (1), 65-72, 2000
1982000
Aspects of MR image distortions in radiotherapy treatment planning
A Fransson, P Andreo, R PŲtter
Strahlentherapie und Onkologie 177 (2), 59-73, 2001
1592001
Stopping power data for high-energy photon beams
P Andreo, A Brahme
Physics in Medicine & Biology 31 (8), 839, 1986
1561986
Ion beam transport in tissue-like media using the Monte Carlo code SHIELD-HIT
I Gudowska, N Sobolevsky, P Andreo, D Belkić, A Brahme
Physics in Medicine & Biology 49 (10), 1933, 2004
1522004
Therapeutic applications of Monte Carlo calculations in nuclear medicine
H Zaidi, G Sgouros
CRC Press, 2002
1442002
Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study
H Benmakhlouf, J Sempau, P Andreo
Medical physics 41 (4), 041711, 2014
1432014
On the clinical spatial resolution achievable with protons and heavier charged particle radiotherapy beams
P Andreo
Physics in Medicine & Biology 54 (11), N205, 2009
1322009
Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV)
J Medin, P Andreo
Physics in Medicine & Biology 42 (1), 89, 1997
1301997
Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams
F SŠnchez-Doblado, P Andreo, R Capote, A Leal, M Perucha, R ArrŠns, ...
Physics in Medicine & Biology 48 (14), 2081, 2003
1292003
Electron beam dose planning using discrete Gaussian beams: mathematical background
A Brahme, I Lax, P Andreo
Acta Radiologica: Oncology 20 (2), 147-158, 1981
1291981
Determination of effective bremsstrahlung spectra and electron contamination for photon dose calculations
A Ahnesjo, P Andreo
Physics in Medicine & Biology 34 (10), 1451, 1989
1131989
Absorbed dose beam quality factors for the dosimetry of high-energy photon beams
P Andreo
Physics in Medicine & Biology 37 (12), 2189, 1992
1091992
Configuration of the electron transport algorithm of PENELOPE to simulate ion chambers
J Sempau, P Andreo
Physics in Medicine & Biology 51 (14), 3533, 2006
1072006
The system can't perform the operation now. Try again later.
Articles 1–20