A study of dipole localization accuracy for MEG and EEG using a human skull phantom RM Leahy, JC Mosher, ME Spencer, MX Huang, JD Lewine Electroencephalography and clinical neurophysiology 107 (2), 159-173, 1998 | 504 | 1998 |
Error bounds for EEG and MEG dipole source localization JC Mosher, ME Spencer, RM Leahy, PS Lewis Electroencephalography and clinical Neurophysiology 86 (5), 303-321, 1993 | 309 | 1993 |
Modulator—amplifier ME Spencer US Patent 7,109,789, 2006 | 98 | 2006 |
Adaptive filters for monitoring localized brain activity from surface potential time series ME Spencer, RM Leahy, JC Mosher, PS Lewis ASILOMAR CONFERENCE ON SIGNALS SYSTEMS AND COMPUTERS, 156-156, 1992 | 92 | 1992 |
Modulator processing for a parametric speaker system JJ Croft III, ME Spencer, JO Norris US Patent 6,584,205, 2003 | 86 | 2003 |
Modulator processing for a parametric speaker system ME Spencer, JJ Croft III, JO Norris US Patent 7,162,042, 2007 | 59 | 2007 |
Modulator processing for a parametric speaker system ME Spencer, JJ Croft III, JO Norris US Patent 7,729,498, 2010 | 29 | 2010 |
Active resonators for control of multiple spinning modes in an axial flow fan inlet B Walker, A Hersh, L Heidelberg, D Sutliff, M Spencer 5th AIAA/CEAS Aeroacoustics Conference and Exhibit, 1853, 1999 | 24 | 1999 |
Dynamic carrier system for parametric arrays J Croft, M Spencer US Patent App. 10/232,755, 2003 | 21* | 2003 |
Dynamic carrier system for parametric arrays ME Spencer, JJ Croft III US Patent 7,224,808, 2007 | 18 | 2007 |
A skull-based multiple dipole phantom for EEG and MEG studies ME Spencer, RM Leahy, JC Mosher Biomag 96: Volume 1/Volume 2 Proceedings of the Tenth International …, 2000 | 10 | 2000 |
Modulator-amplifier ME Spencer US Patent 7,224,219, 2007 | 8 | 2007 |
Modulator processing for a parametric speaker system ME Spencer Acoustical Society of America Journal 128 (5), 3266, 2010 | 7 | 2010 |
Modeling versus accuracy in EEG and MEG data JC Mosher, M Huang, RM Leahy, ME Spencer Los Alamos National Lab.(LANL), Los Alamos, NM (United States), 1997 | 6 | 1997 |
Error bounds for MEG and EEG source localization JC Mosher, ME Spencer, RM Leahy, PS Lewis Conference Record of the Twenty-Sixth Asilomar Conference on Signals …, 1992 | 6 | 1992 |
200 Comparing the source localization accuracy of EEG and MEG for different head modeling techniques using a human skull phantom M Huang, RM Leahy, JC Mosher, ME Spencer International Journal of Psychophysiology 1 (30), 79, 1998 | 4 | 1998 |
Development and demonstration of active noise control concepts R Kraft, Z Hu, S Sommerfeldt, B Walker, A Hersh, H Luo, M Spencer, ... | 3 | 2000 |
Spatio-temporal modeling, estimation and detection for EEG and MEG ME Spencer University of Southern California, 1995 | 3 | 1995 |
A multi-channel demultiplexer/demodulator architecture, simulation and implementation P Cangiane, HA Courtois, DD Lee, MA Sherry, ME Spencer Space communications 10 (1), 25-37, 1992 | 2 | 1992 |
Stochastic process test techniques P Parhami, ME Spencer, JT Robinson, TM Rynne 1993 International Symposium on Electromagnetic Compatibility, 222-225, 1993 | 1 | 1993 |