Follow
Simona Hodis
Simona Hodis
Verified email at tamuk.edu
Title
Cited by
Cited by
Year
Variability of computational fluid dynamics solutions for pressure and flow in a giant aneurysm: the ASME 2012 Summer Bioengineering Conference CFD Challenge
DA Steinman, Y Hoi, P Fahy, L Morris, MT Walsh, N Aristokleous, ...
Journal of biomechanical engineering 135 (2), 021016, 2013
1742013
The computational fluid dynamics rupture challenge 2013—phase II: variability of hemodynamic simulations in two intracranial aneurysms
P Berg, C Roloff, O Beuing, S Voss, SI Sugiyama, N Aristokleous, ...
Journal of biomechanical engineering 137 (12), 121008, 2015
1072015
Real-world variability in the prediction of intracranial aneurysm wall shear stress: the 2015 international aneurysm CFD challenge
K Valen-Sendstad, AW Bergersen, Y Shimogonya, L Goubergrits, ...
Cardiovascular engineering and technology 9, 544-564, 2018
982018
Multiple aneurysms anatomy challenge 2018 (MATCH): phase I: segmentation
P Berg, S Voß, S Saalfeld, G Janiga, AW Bergersen, K Valen-Sendstad, ...
Cardiovascular engineering and technology 9, 565-581, 2018
812018
Analysis of hemodynamics and aneurysm occlusion after flow-diverting treatment in rabbit models
JR Cebral, F Mut, M Raschi, S Hodis, YH Ding, BJ Erickson, R Kadirvel, ...
American Journal of Neuroradiology 35 (8), 1567-1573, 2014
672014
Mechanical events within the arterial wall: the dynamic context for elastin fatigue
S Hodis, M Zamir
Journal of biomechanics 42 (8), 1010-1016, 2009
472009
Grid convergence errors in hemodynamic solution of patient-specific cerebral aneurysms
S Hodis, S Uthamaraj, AL Smith, KD Dennis, DF Kallmes, ...
Journal of biomechanics 45 (16), 2907-2913, 2012
402012
Mechanical events within the arterial wall under the forces of pulsatile flow: A review
S Hodis, M Zamir
Journal of the Mechanical behavior of biomedical materials 4 (8), 1595-1602, 2011
312011
Computational fluid dynamics simulation of an anterior communicating artery ruptured during angiography
S Hodis, S Uthamaraj, G Lanzino, DF Kallmes, D Dragomir-Daescu
Journal of neurointerventional surgery 6 (2), e14-e14, 2014
302014
Pulse wave velocity as a diagnostic Index: The pitfalls of tethering versus stiffening of the arterial wall
S Hodis, M Zamir
Journal of Biomechanics 44 (7), 1367-1373, 2011
292011
Arterial wall tethering as a distant boundary condition
S Hodis, M Zamir
Physical Review E 80 (5), 051913, 2009
262009
Artery length sensitivity in patient-specific cerebral aneurysm simulations
S Hodis, S Kargar, DF Kallmes, D Dragomir-Daescu
American Journal of Neuroradiology 36 (4), 737-743, 2015
222015
Impacts of waveforms on the fluid flow, wall shear stress, and flow distribution in cerebral aneurysms and the development of a universal reduced pressure
NM Naughton, BD Plourde, JR Stark, S Hodis, JP Abraham
Journal of Biomedical Science and Engineering 2014, 2014
222014
Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model
S Hodis, YH Ding, D Dai, R Lingineni, F Mut, J Cebral, D Kallmes, ...
Journal of neurointerventional surgery 8 (1), 94-98, 2016
212016
Solutions of the Maxwell viscoelastic equations for displacement and stress distributions within the arterial wall
S Hodis, M Zamir
Physical Review E 78 (2), 021914, 2008
182008
500 examples and problems of applied differential equations
RP Agarwal, S Hodis, D O'Regan
Springer, 2019
172019
Coupled radial and longitudinal displacements and stresses within the arterial wall in pulsatile flow under tethered and free-wall conditions
S Hodis, M Zamir
Physical Review E 83 (5), 051923, 2011
112011
Pulse wave velocity as a diagnostic index: The effect of wall thickness
S Hodis
Physical Review E 97 (6), 062401, 2018
72018
Adaptive grid generation in a patient-specific cerebral aneurysm
S Hodis, DF Kallmes, D Dragomir-Daescu
Physical Review E 88 (5), 052720, 2013
62013
Nonlinear boundary value problems
RP Agarwal, S Hodis, D O’Regan, RP Agarwal, S Hodis, D O’Regan
500 Examples and Problems of Applied Differential Equations, 293-378, 2019
42019
The system can't perform the operation now. Try again later.
Articles 1–20