Maciej Orkisz
Maciej Orkisz
professeur d'informatique, Université Claude Bernard Lyon 1, CREATIS, France
Verified email at creatis.insa-lyon.fr
TitleCited byYear
Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
M Schaap, CT Metz, T van Walsum, AG van der Giessen, AC Weustink, ...
Medical Image Analysis 13 (5), 701-714, 2009
2742009
Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography
HA Kirişli, M Schaap, CT Metz, AS Dharampall, WB Meijboom, ...
Medical Image Analysis 17 (8), 859–876, 2013
982013
Improved vessel visualization in MR angiography by nonlinear anisotropic filtering
MM Orkisz, C Bresson, IE Magnin, O Champin, PC Douek
Magnetic Resonance in Medicine 37 (6), 914-919, 1997
941997
Computer-assisted Analysis of Three-dimensional MR Angiograms
M Hernández-Hoyos, M Orkisz, P Puech, C Mansard-Desbleds, P Douek, ...
RadioGraphics 22 (2), 421-436, 2002
802002
Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study
RD Rudyanto, S Kerkstra, EM Van Rikxoort, C Fetita, PY Brillet, C Lefevre, ...
Medical image analysis 18 (7), 1217-1232, 2014
772014
Evaluation framework for carotid bifurcation lumen segmentation and stenosis grading
K Hameeteman, MA Zuluaga, M Freiman, L Joskowicz, O Cuisenaire, ...
Medical Image Analysis 15 (4), 477-488, 2011
722011
Evaluation of a Kalman-based block matching method to assess the bi-dimensional motion of the carotid artery wall in B-mode ultrasound sequences
G Zahnd, M Orkisz, A Sérusclat, P Moulin, D Vray
Medical Image Analysis 17, 573–585, 2013
532013
A Deformable Vessel Model with Single Point Initialization for Segmentation, Quantification, and Visualization of Blood Vessels in 3D MRA
M Hernández-Hoyos, A Anwander, M Orkisz, JP Roux, P Douek, ...
International Conference on Medical Image Computing and Computer-Assisted …, 2000
532000
Recursive tracking of vascular tree axes in 3D medical images
JF Carrillo, M Hernández Hoyos, EE Dávila, M Orkisz
International Journal of Computer Assisted Radiology and Surgery 1 (6), 331-339, 2007
442007
Image based renal stone tracking to improve efficacy in extracorporeal lithotripsy
M Orkisz, T Farchtchian, D Saighi, M Bourlion, N Thiounn, G Gimenez, ...
The Journal of urology 160 (4), 1237-1240, 1998
431998
Vascular centerline extraction in 3D MR angiograms for phase contrast MRI blood flow measurement
M Hernández Hoyos, P Orłowski, E Piątkowska-Janko, P Bogorodzki, ...
International Journal of Computer Assisted Radiology and Surgery 1 (1), 51-61, 2006
362006
3D graphical models for vascular-stent pose simulation
L Flórez-Valencia, J Montagnat, M Orkisz
Machine Graphics and Vision, International Journal 13 (3), 235-248, 2004
342004
Estimation du flot optique en présence de discontinuités: une revue
M Orkisz, P Clarysse
Traitement du signal 13 (5), 489-513, 1996
331996
Assessment of carotid artery stenoses in 3D contrast-enhanced magnetic resonance angiography, based on improved generation of the centerline
M Hernández Hoyos, M Orkisz, PC Douek, IE Magnin
Machine Graphics & Vision International Journal 14 (4), 349-378, 2005
30*2005
Automatic detection of abnormal vascular cross-sections based on Density Level Detection and Support Vector Machines
MA Zuluaga, IE Magnin, M Hernández Hoyos, EJF Delgado Leyton, ...
International Journal of Computer Assisted Radiology and Surgery 6 (2), 163-174, 2011
262011
Efficient computation of Hessian-based enhancement filters for tubular structures in 3D images
P Orłowski, M Orkisz
IRBM 30 (3), 128-132, 2009
252009
Simultaneous extraction of carotid artery intima-media interfaces in ultrasound images: assessment of wall thickness temporal variation during the cardiac cycle
G Zahnd, M Orkisz, A Sérusclat, P Moulin, D Vray
International Journal of Computer Assisted Radiology and Surgery 9 (4), 645-658, 2014
242014
Deterministic and stochastic state model of right generalized cylinder (RGC-sm): application in computer phantoms synthesis
J Azencot, M Orkisz
Graphical models 65 (6), 323-350, 2003
242003
Segmentation and quantification of blood vessels in 3D images using a right generalized cylinder state model
L Flórez-Valencia, J Azencot, F Vincent, M Orkisz, IE Magnin
IEEE International Conference on Image Processing, ICIP, 2441-2444, 2006
222006
Quantification of multicontrast vascular MR images with NLSnake, an active contour model: in vitro validation and in vivo evaluation
C Desbleds Mansard, EP Canet Soulas, A Anwander, L Chaabane, ...
Magnetic Resonance in Medicine: An Official Journal of the International …, 2004
222004
The system can't perform the operation now. Try again later.
Articles 1–20