Oreste Fecarotta
Oreste Fecarotta
Verified email at unina.it
Title
Cited by
Cited by
Year
Energy production in water distribution networks: A PAT design strategy
A Carravetta, G Del Giudice, O Fecarotta, HM Ramos
Water resources management 26 (13), 3947-3959, 2012
1632012
PAT design strategy for energy recovery in water distribution networks by electrical regulation
A Carravetta, G Del Giudice, O Fecarotta, HM Ramos
Energies 6 (1), 411-424, 2013
1262013
Banki-Michell optimal design by computational fluid dynamics testing and hydrodynamic analysis
V Sammartano, C Aric˛, A Carravetta, O Fecarotta, T Tucciarelli
Energies 6 (5), 2362-2385, 2013
1052013
Hydropower potential in water distribution networks: Pressure control by PATs
O Fecarotta, C Aric˛, A Carravetta, R Martino, HM Ramos
Water resources management 29 (3), 699-714, 2015
942015
Pump as turbine (PAT) design in water distribution network by system effectiveness
A Carravetta, G Del Giudice, O Fecarotta, HM Ramos
Water 5 (3), 1211-1225, 2013
752013
An improved affinity model to enhance variable operating strategy for pumps used as turbines
O Fecarotta, A Carravetta, HM Ramos, R Martino
Journal of Hydraulic Research 54 (3), 332-341, 2016
602016
Cost-benefit analysis for hydropower production in water distribution networks by a pump as turbine
A Carravetta, O Fecarotta, M Sinagra, T Tucciarelli
Journal of Water Resources Planning and Management 140 (6), 04014002, 2014
602014
CFD and comparisons for a pump as turbine: Mesh reliability and performance concerns.
O Fecarotta, A Carravetta, HM Ramos
International Journal of Energy & Environment 2 (1), 2011
562011
Energy recovery in water systems by PATs: A comparisons among the different installation schemes
A Carravetta, O Fecarotta, G Del Giudice, H Ramos
Procedia Engineering 70, 275-284, 2014
522014
Numerical simulation on pump as turbine: Mesh reliability and performance concerns
A Carravetta, O Fecarotta, H Ramos
2011 International Conference on Clean Electrical Power (ICCEP), 169-174, 2011
342011
Optimal location of pump as turbines (PATs) in water distribution networks to recover energy and reduce leakage
O Fecarotta, A McNabola
Water resources management 31 (15), 5043-5059, 2017
332017
PAT efficiency variation with design parameters
A Carravetta, O Fecarotta, R Martino, L Antipodi
Procedia Engineering 70, 285-291, 2014
282014
A new low-cost installation scheme of PATs for pico-hydropower to recover energy in residential areas
A Carravetta, O Fecarotta, HM Ramos
Renewable Energy 125, 1003-1014, 2018
262018
Energy saving in a water supply network by coupling a pump and a pump as turbine (PAT) in a turbopump
A Carravetta, L Antipodi, U Golia, O Fecarotta
Water 9 (1), 62, 2017
262017
Fine tuning a PAT hydropower plant in a water supply network to improve system effectiveness
O Fecarotta, HM Ramos, S Derakhshan, G Del Giudice, A Carravetta
Journal of Water Resources Planning and Management 144 (8), 04018038, 2018
242018
Evaluation of PAT Performances by Modified Affinity Law.
A Carravetta, MC Conte, O Fecarotta, HM Ramos
Procedia Engineering 89, 581-587, 2014
192014
A comparison of energy recovery by PATs against direct variable speed pumping in water distribution networks
MC Morani, A Carravetta, G Del Giudice, A McNabola, O Fecarotta
Fluids 3 (2), 41, 2018
142018
Hydraulic design of a USBR Type II stilling basin
R Padulano, O Fecarotta, G Del Giudice, A Carravetta
Journal of Irrigation and Drainage Engineering 143 (5), 04017001, 2017
142017
Optimization of osmotic desalination plants for water supply networks
A Carravetta, O Fecarotta, UM Golia, M La Rocca, R Martino, R Padulano, ...
Water Resources Management 30 (11), 3965-3978, 2016
132016
Optimal pump scheduling for urban drainage under variable flow conditions
O Fecarotta, A Carravetta, MC Morani, R Padulano
Resources 7 (4), 73, 2018
102018
The system can't perform the operation now. Try again later.
Articles 1–20