Bioassay of prostate-specific antigen (PSA) using microcantilevers G Wu, RH Datar, KM Hansen, T Thundat, RJ Cote, A Majumdar Nature biotechnology 19 (9), 856-860, 2001 | 1341 | 2001 |
Adsorption‐induced surface stress and its effects on resonance frequency of microcantilevers GY Chen, T Thundat, EA Wachter, RJ Warmack Journal of Applied Physics 77 (8), 3618-3622, 1995 | 739 | 1995 |
Origin of nanomechanical cantilever motion generated from biomolecular interactions G Wu, H Ji, K Hansen, T Thundat, R Datar, R Cote, MF Hagan, ... Proceedings of the National Academy of Sciences 98 (4), 1560-1564, 2001 | 676 | 2001 |
Detection of mercury vapor using resonating microcantilevers T Thundat, EA Wachter, SL Sharp, RJ Warmack Applied Physics Letters 66 (13), 1695-1697, 1995 | 646 | 1995 |
Nanotechnologies for biomolecular detection and medical diagnostics MMC Cheng, G Cuda, YL Bunimovich, M Gaspari, JR Heath, HD Hill, ... Current opinion in chemical biology 10 (1), 11-19, 2006 | 596 | 2006 |
Thermal and ambient‐induced deflections of scanning force microscope cantilevers T Thundat, RJ Warmack, GY Chen, DP Allison Applied Physics Letters 64 (21), 2894-2896, 1994 | 594 | 1994 |
Recent developments of carbon-based electrocatalysts for hydrogen evolution reaction W Zhou, J Jia, J Lu, L Yang, D Hou, G Li, S Chen Nano Energy 28, 29-43, 2016 | 553 | 2016 |
Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches KM Hansen, HF Ji, G Wu, R Datar, R Cote, A Majumdar, T Thundat Analytical Chemistry 73 (7), 1567-1571, 2001 | 518 | 2001 |
Nanosensors for trace explosive detection L Senesac, TG Thundat materials today 11 (3), 28-36, 2008 | 397 | 2008 |
Resonance response of scanning force microscopy cantilevers GY Chen, RJ Warmack, T Thundat, DP Allison, A Huang Review of Scientific Instruments 65 (8), 2532-2537, 1994 | 376 | 1994 |
Microcantilever sensors T Thundat, PI Oden, RJ Warmack Microscale Thermophysical Engineering 1 (3), 185-199, 1997 | 357 | 1997 |
Preparation and characterization of STM tips for electrochemical studies LA Nagahara, T Thundat, SM Lindsay Review of scientific instruments 60 (10), 3128-3130, 1989 | 351 | 1989 |
Glucose biosensor based on the microcantilever J Pei, F Tian, T Thundat Analytical Chemistry 76 (2), 292-297, 2004 | 350 | 2004 |
Vapor detection using resonating microcantilevers T Thundat, GY Chen, RJ Warmack, DP Allison, EA Wachter Analytical Chemistry 67 (3), 519-521, 1995 | 336 | 1995 |
Gold grown epitaxially on mica: conditions for large area flat faces JA DeRose, T Thundat, LA Nagahara, SM Lindsay Surface Science 256 (1-2), 102-108, 1991 | 326 | 1991 |
Microcantilever biosensors KM Hansen, T Thundat Methods 37 (1), 57-64, 2005 | 324 | 2005 |
Carbon fiber doped thermosetting elastomer for flexible sensors: physical properties and microfabrication A Khosla, S Shah, MD Shiblee, SH Mir, LA Nagahara, T Thundat, ... Scientific reports 8 (1), 1-8, 2018 | 280 | 2018 |
Sensitive detection of plastic explosives with self-assembled monolayer-coated microcantilevers LA Pinnaduwage, V Boiadjiev, JE Hawk, T Thundat Applied Physics Letters 83 (7), 1471-1473, 2003 | 274 | 2003 |
Organic-inorganic hybrid functional materials: An integrated platform for applied technologies SH Mir, LA Nagahara, T Thundat, P Mokarian-Tabari, H Furukawa, ... Journal of The Electrochemical Society 165 (8), B3137-B3156, 2018 | 264 | 2018 |
In-vivo orthopedic implant diagnostic device for sensing load, wear, and infection BMC Evans III, TG Thundat, RD Komistek, DA Dennis, M Mahfouz US Patent 7,097,662, 2006 | 264 | 2006 |