Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion J Lee, K Matsumura, K Yamakoshi, P Rolfe, S Tanaka, T Yamakoshi 2013 35th annual international conference of the IEEE engineering in …, 2013 | 245 | 2013 |
Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry K Yamakoshi, Y Yamakoshi Journal of Biomedical Optics 11 (5), 054028-054028-9, 2006 | 152 | 2006 |
Cuffless blood pressure estimation using only a smartphone K Matsumura, P Rolfe, S Toda, T Yamakoshi Scientific reports 8 (1), 1-9, 2018 | 104 | 2018 |
iPhysioMeter: A new approach for measuring heart rate and normalized pulse volume using only a smartphone K Matsumura, T Yamakoshi Behavior Research Methods 45 (4), 1272-1278, 2013 | 92 | 2013 |
iPhone 4s Photoplethysmography: Which Light Color Yields the Most Accurate Heart Rate and Normalized Pulse Volume Using the iPhysioMeter Application in the Presence of Motion … K Matsumura, P Rolfe, J Lee, T Yamakoshi PloS One 9 (3), e91205, 2014 | 89 | 2014 |
Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: towards applications in ambulatory monitoring J Lee, K Matsumura, T Yamakoshi, P Rolfe, N Tanaka, K Kim, ... Physiological Measurement 34 (3), 359, 2013 | 64 | 2013 |
A preliminary study on driver's stress index using a new method based on differential skin temperature measurement T Yamakoshi, K Yamakoshi, S Tanaka, M Nogawa, M Shibata, Y Sawada, ... 2007 29th Annual International Conference of the IEEE Engineering in …, 2007 | 56 | 2007 |
Feasibility study on driver's stress detection from differential skin temperature measurement T Yamakoshi, K Yamakoshi, S Tanaka, M Nogawa, SB Park, M Shibata, ... 2008 30th annual international conference of the ieee engineering in …, 2008 | 51 | 2008 |
Relationship between salivary Chromogranin-A and stress induced by simulated monotonous driving T Yamakoshi, SB Park, WC Jang, K Kim, Y Yamakoshi, H Hirose Medical & Biological Engineering & Computing 47 (4), 449-456, 2009 | 50 | 2009 |
A new non-invasive method for measuring blood glucose using instantaneous differential near infrared spectrophotometry Y Yamakoshi, M Ogawa, T Yamakoshi, M Satoh, M Nogawa, S Tanaka, ... 2007 29th Annual International Conference of the IEEE Engineering in …, 2007 | 45 | 2007 |
Accuracy assessment of a noninvasive device for monitoring beat-by-beat blood pressure in the radial artery using the volume-compensation method S Tanaka, M Nogawa, T Yamakoshi, K Yamakoshi IEEE Transactions on Biomedical engineering 54 (10), 1892-1895, 2007 | 43 | 2007 |
A novel physiological index for Driver’s Activation State derived from simulated monotonous driving studies T Yamakoshi, P Rolfe, Y Yamakoshi, H Hirose Transportation Research Part C: Emerging Technologies 17 (1), 69-80, 2009 | 38 | 2009 |
Physiological measurements and analyses in motor sports: a preliminary study in racing kart athletes T Yamakoshi, K Matsumura, Y Yamakoshi, H Hirose, P Rolfe European Journal of Sport Science 10 (6), 397-406, 2010 | 36 | 2010 |
The effect of competition on heart rate during kart driving: A field study K Matsumura, T Yamakoshi, Y Yamakoshi, P Rolfe BMC Research Notes 4 (1), 342, 2011 | 33 | 2011 |
Assessment of slow-breathing relaxation technique in acute stressful tasks using a multipurpose non-invasive beat-by-beat cardiovascular monitoring system M Nogawa, T Yamakoshi, A Ikarashi, S Tanaka, K Yamakoshi 2007 29th Annual International Conference of the IEEE Engineering in …, 2007 | 28 | 2007 |
Side-scattered finger-photoplethysmography: experimental investigations toward practical noninvasive measurement of blood glucose Y Yamakoshi, K Matsumura, T Yamakoshi, J Lee, P Rolfe, Y Kato, ... Journal of biomedical optics 22 (6), 067001-067001, 2017 | 27 | 2017 |
Fish consumption and cardiovascular response during mental stress K Matsumura, T Yamakoshi, H Noguchi, P Rolfe, Y Matsuoka BMC Research Notes 5 (1), 288, 2012 | 27 | 2012 |
Biosignal measurement apparatus JY Lee, K Yamakoshi, KS Shin, HJ Jung, S Tanaka, T Yamakoshi US Patent 8,301,215, 2012 | 25 | 2012 |
Advanced volume-compensation method for indirect finger arterial pressure determination: comparison with brachial sphygmomanometry K Matsumura, T Yamakoshi, P Rolfe, K Yamakoshi IEEE Transactions on Biomedical Engineering 64 (5), 1131-1137, 2016 | 22 | 2016 |
iPhysioMeter: a smartphone photoplethysmograph for measuring various physiological indices K Matsumura, P Rolfe, T Yamakoshi Mobile Health Technologies: Methods and Protocols, 305-326, 2015 | 20 | 2015 |