Follow
George Ding
Title
Cited by
Cited by
Year
BEAM: a Monte Carlo code to simulate radiotherapy treatment units
DWO Rogers, BA Faddegon, GX Ding, CM Ma, J We, TR Mackie
Medical physics 22 (5), 503-524, 1995
18771995
Small fields: nonequilibrium radiation dosimetry
IJ Das, GX Ding, A Ahnesjö
Medical physics 35 (1), 206-215, 2008
8902008
A study on adaptive IMRT treatment planning using kV cone-beam CT
GX Ding, DM Duggan, CW Coffey, M Deeley, DE Hallahan, A Cmelak, ...
Radiotherapy and Oncology 85 (1), 116-125, 2007
2702007
Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator
GX Ding
Physics in Medicine & Biology 47 (7), 1025, 2002
2332002
Accurate patient dosimetry of kilovoltage cone‐beam CT in radiation therapy
GX Ding, DM Duggan, CW Coffey
Medical physics 35 (3), 1135-1144, 2008
2092008
Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure
GX Ding, CW Coffey
International Journal of Radiation Oncology* Biology* Physics 73 (2), 610-617, 2009
2042009
Calculation of stopping‐power ratios using realistic clinical electron beams
GX Ding, DWO Rogers, TR Mackie
Medical physics 22 (5), 489-501, 1995
1601995
Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy
GX Ding, DM Duggan, CW Coffey
Physics in Medicine & Biology 52 (6), 1595, 2007
1542007
Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning
JE Cygler, GM Daskalov, GH Chan, GX Ding
Medical physics 31 (1), 142-153, 2004
1532004
R50 as a beam quality specifier for selecting stopping‐power ratios and reference depths for electron dosimetry
DT Burns, GX Ding, DWO Rogers
Medical physics 23 (3), 383-388, 1996
1491996
Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180
GX Ding, P Alaei, B Curran, R Flynn, M Gossman, TR Mackie, M Miften, ...
Medical physics 45 (5), e84-e99, 2018
1372018
Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods
GX Ding, DM Duggan, CW Coffey
Physics in Medicine & Biology 51 (10), 2549, 2006
1372006
Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study
MA Deeley, A Chen, R Datteri, JH Noble, AJ Cmelak, EF Donnelly, ...
Physics in Medicine & Biology 56 (14), 4557, 2011
1332011
Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy
GX Ding, DM Duggan, B Lu, DE Hallahan, A Cmelak, A Malcolm, ...
Medical physics 34 (7), 2985-2994, 2007
1172007
Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose
GX Ding, P Munro
Radiotherapy and Oncology 108 (1), 91-98, 2013
1092013
Reducing radiation exposure to patients from kV-CBCT imaging
GX Ding, P Munro, J Pawlowski, A Malcolm, CW Coffey
Radiotherapy and Oncology 97 (3), 585-592, 2010
1082010
ICRU Report 91: Prescribing, recording, and reporting of stereotactic treatments with small photon beams
J Seuntjens
J ICRU 14, 2014
1072014
A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm
GX Ding, JE Cygler, WY Christine, NI Kalach, G Daskalov
International Journal of Radiation Oncology* Biology* Physics 63 (2), 622-633, 2005
1032005
Energy spectra, angular spread, and dose distributions of electron beams from various accelerators used in radiotherapy
GX Ding, DWO Rogers
National Research Council of Canada Report, 1995
971995
A study on beams passing through hip prosthesis for pelvic radiation treatment
GX Ding, WY Christine
International Journal of Radiation Oncology* Biology* Physics 51 (4), 1167-1175, 2001
942001
The system can't perform the operation now. Try again later.
Articles 1–20