The impact of shading design and control on building cooling and lighting demand A Tzempelikos, AK Athienitis Solar energy 81 (3), 369-382, 2007 | 824 | 2007 |
Investigation of the thermal performance of a passive solar test-room with wall latent heat storage AK Athienitis, C Liu, D Hawes, D Banu, D Feldman Building and environment 32 (5), 405-410, 1997 | 665 | 1997 |
Manually-operated window shade patterns in office buildings: A critical review W O'Brien, K Kapsis, AK Athienitis Building and Environment 60, 319-338, 2013 | 331 | 2013 |
Airflow assessment in cross-ventilated buildings with operable façade elements P Karava, T Stathopoulos, AK Athienitis Building and environment 46 (1), 266-279, 2011 | 329 | 2011 |
Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 1, BIPV/T system and house … Y Chen, AK Athienitis, K Galal Solar energy 84 (11), 1892-1907, 2010 | 288 | 2010 |
Thermal analysis and design of passive solar buildings AK Athienitis, M Santamouris Routledge, 2013 | 262 | 2013 |
A review of research and developments of building-integrated photovoltaic/thermal (BIPV/T) systems T Yang, AK Athienitis Renewable and Sustainable Energy Reviews 66, 886-912, 2016 | 253 | 2016 |
A methodology for simulation of daylight room illuminance distribution and light dimming for a room with a controlled shading device AK Athienitis, A Tzempelikos Solar energy 72 (4), 271-281, 2002 | 235 | 2002 |
PCM thermal storage design in buildings: Experimental studies and applications to solaria in cold climates F Guarino, A Athienitis, M Cellura, D Bastien Applied energy 185, 95-106, 2017 | 198 | 2017 |
Modeling, design, and optimization of net-zero energy buildings AK Athienitis, W O'Brien Ernst & Sohn, 2015 | 196 | 2015 |
A prototype photovoltaic/thermal system integrated with transpired collector AK Athienitis, J Bambara, B O’Neill, J Faille Solar Energy 85 (1), 139-153, 2011 | 193 | 2011 |
Parametric investigation of geometric form effects on solar potential of housing units C Hachem, A Athienitis, P Fazio Solar Energy 85 (9), 1864-1877, 2011 | 187 | 2011 |
Indoor thermal environmental conditions near glazed facades with shading devices–Part I: Experiments and building thermal model M Bessoudo, A Tzempelikos, AK Athienitis, R Zmeureanu Building and environment 45 (11), 2506-2516, 2010 | 183 | 2010 |
Direct solar energy D Arvizu, P Balaya, LF Cabeza, KGT Hollands, A Jäger-Waldau, M Kondo, ... Renewable Energy Sources and Climate Change Mitigation, 333-400, 2011 | 182 | 2011 |
Wind driven flow through openings–a review of discharge coefficients P Karava, T Stathopoulos, AK Athienitis International journal of ventilation 3 (3), 255-266, 2004 | 175 | 2004 |
A study of design options for a building integrated photovoltaic/thermal (BIPV/T) system with glazed air collector and multiple inlets T Yang, AK Athienitis Solar Energy 104, 82-92, 2014 | 174 | 2014 |
The effect of solar radiation on dynamic thermal performance of floor heating systems AK Athienitis, Y Chen Solar energy 69 (3), 229-237, 2000 | 161 | 2000 |
Wind-induced natural ventilation analysis P Karava, T Stathopoulos, AK Athienitis Solar Energy 81 (1), 20-30, 2007 | 155 | 2007 |
Indoor thermal environmental conditions near glazed facades with shading devices–Part II: Thermal comfort simulation and impact of glazing and shading properties A Tzempelikos, M Bessoudo, AK Athienitis, R Zmeureanu Building and environment 45 (11), 2517-2525, 2010 | 151 | 2010 |
Optimization of the performance of double-facades with integrated photovoltaic panels and motorized blinds R Charron, AK Athienitis Solar Energy 80 (5), 482-491, 2006 | 149 | 2006 |