Follow
Jean-Francois Carrier
Jean-Francois Carrier
Verified email at umontreal.ca
Title
Cited by
Cited by
Year
Report of the Task Group 186 on model‐based dose calculation methods in brachytherapy beyond the TG‐43 formalism: current status and recommendations for clinical implementation
L Beaulieu, Å Carlsson Tedgren, JF Carrier, SD Davis, F Mourtada, ...
Medical physics 39 (10), 6208-6236, 2012
5252012
Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
M Bazalova, JF Carrier, L Beaulieu, F Verhaegen
Physics in Medicine & Biology 53 (9), 2439, 2008
2612008
Validation of GEANT4, an object‐oriented Monte Carlo toolkit, for simulations in medical physics
JF Carrier, L Archambault, L Beaulieu, R Roy
Medical physics 31 (3), 484-492, 2004
2272004
A stoichiometric calibration method for dual energy computed tomography
AE Bourque, JF Carrier, H Bouchard
Physics in Medicine & Biology 59 (8), 2059, 2014
1772014
On the characterization and uncertainty analysis of radiochromic film dosimetry
H Bouchard, F Lacroix, G Beaudoin, JF Carrier, I Kawrakow
Medical physics 36 (6Part1), 1931-1946, 2009
1672009
Ionization chamber gradient effects in nonstandard beam configurations
H Bouchard, J Seuntjens, JF Carrier, I Kawrakow
Medical physics 36 (10), 4654-4663, 2009
1172009
Impact of interseed attenuation and tissue composition for permanent prostate implants
JF Carrier, L Beaulieu, F Therriault‐Proulx, R Roy
Medical physics 33 (3), 595-604, 2006
992006
Postimplant dosimetry using a Monte Carlo dose calculation engine: a new clinical standard
JF Carrier, M D’Amours, F Verhaegen, B Reniers, AG Martin, E Vigneault, ...
International Journal of Radiation Oncology* Biology* Physics 68 (4), 1190-1198, 2007
922007
Predictive parameters of CyberKnife fiducial-less (XSight Lung) applicability for treatment of early non-small cell lung cancer: a single-center experience
H Bahig, MP Campeau, T Vu, R Doucet, DB Nadeau, B Fortin, D Roberge, ...
International Journal of Radiation Oncology* Biology* Physics 87 (3), 583-589, 2013
862013
ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy
H Afsharpour, G Landry, M D’Amours, S Enger, B Reniers, E Poon, ...
Physics in Medicine & Biology 57 (11), 3273, 2012
862012
Tissue segmentation in Monte Carlo treatment planning: a simulation study using dual-energy CT images
M Bazalova, JF Carrier, L Beaulieu, F Verhaegen
Radiotherapy and Oncology 86 (1), 93-98, 2008
782008
Overview of Geant4 applications in medical physics
L Archambault, L Beaulieu, JF Carrier, F Castrovillari, S Chauvie, ...
2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No …, 2003
662003
Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant
H Afsharpour, JP Pignol, B Keller, JF Carrier, B Reniers, F Verhaegen, ...
Physics in Medicine & Biology 55 (16), 4547, 2010
552010
Migration of intraprostatic fiducial markers and its influence on the matching quality in external beam radiation therapy for prostate cancer
G Delouya, JF Carrier, D Béliveau-Nadeau, D Donath, D Taussky
Radiotherapy and Oncology 96 (1), 43-47, 2010
522010
A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants
H Afsharpour, M D’Amours, B Coté, JF Carrier, F Verhaegen, L Beaulieu
Medical physics 35 (8), 3671-3681, 2008
502008
Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant
C Furstoss, B Reniers, MJ Bertrand, E Poon, JF Carrier, BM Keller, ...
Medical physics 36 (5), 1848-1858, 2009
432009
Hemoglobin level in cervical cancer: a surrogate for an infiltrative phenotype
M Barkati, I Fortin, L Mileshkin, D Bernshaw, JF Carrier, K Narayan
International Journal of Gynecologic Cancer 23 (4), 2013
382013
Dosimetric impact and theoretical clinical benefits of fiducial markers for dose escalated prostate cancer radiation treatment
I Gauthier, JF Carrier, D Béliveau-Nadeau, B Fortin, D Taussky
International Journal of Radiation Oncology* Biology* Physics 74 (4), 1128-1133, 2009
332009
Assessing lung function using contrast‐enhanced dual‐energy computed tomography for potential applications in radiation therapy
A Lapointe, H Bahig, D Blais, H Bouchard, É Filion, JF Carrier, S Bedwani
Medical physics 44 (10), 5260-5269, 2017
312017
Validation of GPUMCD for low‐energy brachytherapy seed dosimetry
S Hissoiny, B Ozell, P Després, JF Carrier
Medical Physics 38 (7), 4101-4107, 2011
312011
The system can't perform the operation now. Try again later.
Articles 1–20