Parminder S. Basran
Parminder S. Basran
Adjunct Professor - Senior Medical Physicist
Verified email at bccancer.bc.ca - Homepage
TitleCited byYear
Phase I/II study of a five-fraction hypofractionated accelerated radiotherapy treatment for low-risk localised prostate cancer: early results of pHART3
CI Tang, DA Loblaw, P Cheung, L Holden, G Morton, PS Basran, R Tirona, ...
Clinical Oncology 20 (10), 729-737, 2008
752008
An analysis of tolerance levels in IMRT quality assurance procedures
PS Basran, MK Woo
Medical physics 35 (6Part1), 2300-2307, 2008
722008
A comparison of two immobilization systems for stereotactic body radiation therapy of lung tumors
K Han, P Cheung, PS Basran, I Poon, L Yeung, F Lochray
Radiotherapy and Oncology 95 (1), 103-108, 2010
712010
Moving from IMRT QA measurements toward independent computer calculations using control charts
T Pawlicki, S Yoo, LE Court, SK McMillan, RK Rice, JD Russell, ...
Radiotherapy and Oncology 89 (3), 330-337, 2008
652008
Advances in technology for intracranial stereotactic radiosurgery
A Sahgal, L Ma, E Chang, A Shiu, DA Larson, N Laperriere, FF Yin, ...
Technology in cancer research & treatment 8 (4), 271-280, 2009
572009
Quantitative characterization of metastatic disease in the spine. Part II. Histogram‐based analyses
C Whyne, M Hardisty, F Wu, T Skrinskas, M Clemons, L Gordon, ...
Medical physics 34 (8), 3279-3285, 2007
352007
Hypofractionated accelerated radiotherapy using concomitant intensity-modulated radiotherapy boost technique for localized high-risk prostate cancer: acute toxicity results
TS Lim, PCF Cheung, DA Loblaw, G Morton, KE Sixel, G Pang, P Basran, ...
International Journal of Radiation Oncology* Biology* Physics 72 (1), 85-92, 2008
342008
Process control analysis of IMRT QA: implications for clinical trials
T Pawlicki, S Yoo, SK McMillan, RK Rice, JD Russell, JM Pacyniak, ...
Physics in Medicine & Biology 53 (18), 5193, 2008
322008
Evaluation of optimized compensators on a 3D planning system
PS Basran, W Ansbacher, GC Field, BR Murray
Medical physics 25 (10), 1837-1844, 1998
311998
Comparison of helical and average computed tomography for stereotactic body radiation treatment planning and normal tissue contouring in lung cancer
K Han, PS Basran, P Cheung
Clinical oncology 22 (10), 862-867, 2010
202010
The impact of dose calculation algorithms on partial and whole breast radiation treatment plans
PS Basran, S Zavgorodni, T Berrang, IA Olivotto, W Beckham
Radiation Oncology 5 (1), 120, 2010
162010
Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison
D Fortin, PS Basran, T Berrang, D Peterson, ES Wai
Radiation Oncology 9 (1), 50, 2014
132014
Cone beam CT (CBCT) evaluation of inter-and intra-fraction motion for patients undergoing brain radiotherapy immobilized using a commercial thermoplastic mask on a robotic couch
AW Lightstone, M Tsao, PS Basran, G Chan, G Pang, L Ma, F Lochray, ...
Technology in cancer research & treatment 11 (3), 203-209, 2012
132012
CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter
PS Basran, A Robertson, D Wells
Medical physics 38 (2), 712-718, 2011
132011
CT, MR, and ultrasound image artifacts from prostate brachytherapy seed implants: the impact of seed size
AKH Robertson, PS Basran, SD Thomas, D Wells
Medical physics 39 (4), 2061-2068, 2012
122012
Functional CT in lung with a conventional scanner: simulations and sampling considerations
PS Basran, I Kay, DP Spencer
Physics in Medicine & Biology 49 (9), 1755, 2004
52004
PROSPECTIVE STUDY OF EXTREME HYPOFRACTIONATED RADIOTHERAPY (35 GY IN FIVE FRACTIONS) FOR LOW-RISK PROSTATE CANCER: TOXICITY RESULTS
H Ouon, P Cheung, A Cesta, L Holden, C Tang, G Pang, G Morton, ...
RADIOTHERAPY AND ONCOLOGY 96, S46-S46, 2010
42010
Sci—Wed PM: Delivery—05: SBRT of Spinal Lesions Utilizing the Elekta Beam Modulator, Hexapod Couch and BodyFIX Systems
D Hyde, PS Basran, G Pang, F Lochray, A Sahgal
Medical Physics 36 (9Part1), 4302-4302, 2009
32009
Dosimetric verification of micro‐MLC based intensity modulated radiation therapy
P Basran, C Yeboah
Journal of applied clinical medical physics 9 (3), 109-121, 2008
32008
Reducing radiation risks to staff for patients with permanently implanted radioactive sources requiring unrelated surgery
PS Basran, P Baxter, WA Beckham
Journal of applied clinical medical physics 16 (5), 159-166, 2015
22015
The system can't perform the operation now. Try again later.