Bartłomiej Grychtol
Bartłomiej Grychtol
Fraunhofer Project Group for Automation in Medicine and Biotechnology
Verified email at ipa.fraunhofer.de
TitleCited byYear
GREIT: a unified approach to 2D linear EIT reconstruction of lung images
A Adler, JH Arnold, R Bayford, A Borsic, B Brown, P Dixon, TJC Faes, ...
Physiological measurement 30 (6), S35, 2009
3882009
Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy …
I Frerichs, MBP Amato, AH Van Kaam, DG Tingay, Z Zhao, B Grychtol, ...
Thorax 72 (1), 83-93, 2017
2042017
Regional lung volume changes in children with acute respiratory distress syndrome during a derecruitment maneuver
GK Wolf, B Grychtol, I Frerichs, HR van Genderingen, D Zurakowski, ...
Critical care medicine 35 (8), 1972-1978, 2007
742007
Impact of model shape mismatch on reconstruction quality in electrical impedance tomography
B Grychtol, WRB Lionheart, M Bodenstein, GK Wolf, A Adler
IEEE transactions on medical imaging 31 (9), 1754-1760, 2012
602012
Towards morphological thoracic EIT: Major signal sources correspond to respective organ locations in CT
D Ferrario, B Grychtol, J Sola, SH Bohm, M Bodenstein
Biomedical Engineering, IEEE Transactions on 59 (11), 1-1, 2012
382012
3D EIT image reconstruction with GREIT
B Grychtol, B Müller, A Adler
Physiological measurement 37 (6), 785, 2016
302016
Regional lung volume changes during high-frequency oscillatory ventilation
GK Wolf, B Grychtol, I Frerichs, D Zurakowski, JH Arnold
Pediatric Critical Care Medicine 11 (5), 610-615, 2010
302010
Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography
G Elke, MK Fuld, AF Halaweish, B Grychtol, N Weiler, EA Hoffman, ...
Physiological measurement 34 (10), 1303, 2013
292013
Uniform background assumption produces misleading lung EIT images
B Grychtol, A Adler
Physiological measurement 34 (6), 579, 2013
252013
Human behavior integration improves classification rates in real-time BCI
B Grychtol, H Lakany, G Valsan, BA Conway
IEEE Transactions on Neural Systems and Rehabilitation Engineering 18 (4 …, 2010
252010
Differences in regional pulmonary pressure–impedance curves before and after lung injury assessed with a novel algorithm
B Grychtol, GK Wolf, JH Arnold
Physiological measurement 30 (6), S137, 2009
242009
FEM electrode refinement for electrical impedance tomography
B Grychtol, A Adler
2013 35th Annual International Conference of the IEEE Engineering in …, 2013
232013
Towards lung EIT image segmentation: Automatic classification of lung tissue state from analysis of EIT monitored recruitment manoeuvres
B Grychtol, GK Wolf, A Adler, JH Arnold
Physiological measurement 31 (8), 2010
222010
An individualized approach to sustained inflation duration at birth improves outcomes in newborn preterm lambs
DG Tingay, A Lavizzari, CEE Zonneveld, A Rajapaksa, E Zannin, ...
American Journal of Physiology-Lung Cellular and Molecular Physiology 309 …, 2015
212015
The strathclyde brain computer interface
G Valsan, B Grychtol, H Lakany, BA Conway
2009 Annual International Conference of the IEEE Engineering in Medicine and …, 2009
192009
Why is EIT so hard, and what are we doing about it
A Adler, B Grychtol, R Bayford
Physiol Meas 36 (6), 1067-1073, 2015
182015
Evaluation and real-time monitoring of data quality in electrical impedance tomography
Y Mamatjan, B Grychtol, P Gaggero, J Justiz, VM Koch, A Adler
IEEE transactions on medical imaging 32 (11), 1997-2005, 2013
182013
Spatiotemporal aeration and lung injury patterns are influenced by the first inflation strategy at birth
DG Tingay, A Rajapaksa, CE Zonneveld, D Black, EJ Perkins, A Adler, ...
American journal of respiratory cell and molecular biology 54 (2), 263-272, 2016
162016
Functional validation and comparison framework for EIT lung imaging
B Grychtol, G Elke, P Meybohm, N Weiler, I Frerichs, A Adler
PLoS One 9 (8), e103045, 2014
162014
Regional overdistension identified with electrical impedance tomography in the perflubron-treated lung
GK Wolf, B Grychtol, TK Boyd, D Zurakowski, JH Arnold
Physiological measurement 31 (8), S85, 2010
152010
The system can't perform the operation now. Try again later.
Articles 1–20