Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study CF Uribe, PL Esquinas, J Tanguay, M Gonzalez, E Gaudin, ... EJNMMI physics 4, 1-20, 2017 | 65 | 2017 |
Determination of gamma camera calibration factors for quantitation of therapeutic radioisotopes W Zhao, PL Esquinas, X Hou, CF Uribe, M Gonzalez, JM Beauregard, ... EJNMMI physics 5, 1-16, 2018 | 52 | 2018 |
Accuracy of kidney dosimetry performed using simplified time activity curve modelling methods: a 177Lu-DOTATATE patient study W Zhao, PL Esquinas, A Frezza, X Hou, JM Beauregard, A Celler Physics in Medicine & Biology 64 (17), 175006, 2019 | 30 | 2019 |
Characteristics of Bremsstrahlung emissions of 177Lu, 188Re, and 90Y for SPECT/CT quantification in radionuclide therapy CF Uribe, PL Esquinas, M Gonzalez, A Celler Physica Medica 32 (5), 691-700, 2016 | 27 | 2016 |
Radioembolization of hepatocellular carcinoma with built-in dosimetry: first in vivo results with uniformly-sized, biodegradable microspheres labeled with 188Re JC De La Vega, PL Esquinas, C Rodríguez-Rodríguez, M Bokharaei, ... Theranostics 9 (3), 868, 2019 | 22 | 2019 |
Deadtime effects in quantification of 177Lu activity for radionuclide therapy CF Uribe, PL Esquinas, M Gonzalez, W Zhao, J Tanguay, A Celler EJNMMI physics 5, 1-16, 2018 | 22 | 2018 |
33S for neutron capture therapy: nuclear data for monte carlo calculations I Porras, M Sabaté-Gilarte, J Praena, JM Quesada, PL Esquinas Nuclear Data Sheets 120, 246-249, 2014 | 19 | 2014 |
Evaluation of 209At as a theranostic isotope for 209At-radiopharmaceutical development using high-energy SPECT JR Crawford, AKH Robertson, H Yang, C Rodríguez-Rodríguez, ... Physics in Medicine & Biology 63 (4), 045025, 2018 | 15 | 2018 |
188Re image performance assessment using small animal multi-pinhole SPECT/PET/CT system PL Esquinas, C Rodríguez-Rodríguez, JC De La Vega, M Bokharaei, ... Physica Medica 33, 26-37, 2017 | 15 | 2017 |
33S as a cooperative capturer for BNCT J Praena, M Sabaté-Gilarte, I Porras, PL Esquinas, JM Quesada, ... Applied Radiation and Isotopes 88, 203-205, 2014 | 14 | 2014 |
Using in vitro lipolysis and SPECT/CT in vivo imaging to understand oral absorption of fenofibrate from lipid-based drug delivery systems T Tran, P Bønløkke, C Rodríguez-Rodríguez, Z Nosrati, PL Esquinas, ... Journal of controlled release 317, 375-384, 2020 | 11 | 2020 |
Biodistribution, pharmacokinetics, and organ-level dosimetry for 188Re-AHDD-Lipiodol radioembolization based on quantitative post-treatment SPECT/CT scans PL Esquinas, A Shinto, KK Kamaleshwaran, J Joseph, A Celler EJNMMI physics 5, 1-22, 2018 | 11 | 2018 |
Learning from our neighbours: a novel approach on sinogram completion using bin-sharing and deep learning to reconstruct high quality 4DCBCT J Beaudry, PL Esquinas, CC Shieh Medical Imaging 2019: Physics of Medical Imaging 10948, 1025-1035, 2019 | 10 | 2019 |
Impact of image reconstruction method on dose distributions derived from 90Y PET images: phantom and liver radioembolization patient studies X Hou, H Ma, PL Esquinas, C Uribe, S Tolhurst, F Bénard, D Liu, ... Physics in Medicine & Biology 65 (21), 215022, 2020 | 9 | 2020 |
Dual SPECT imaging of 111In and 67Ga to simultaneously determine in vivo the pharmacokinetics of different radiopharmaceuticals: a quantitative tool in pre-clinical research PL Esquinas, C Rodríguez-Rodríguez, TVF Esposito, J Harboe, ... Physics in Medicine & Biology 63 (23), 235029, 2018 | 9 | 2018 |
Comparison of rhenium and iodine as contrast agents in X-ray imaging JC De La Vega, PL Esquinas, JK Gill, S Jessa, B Gill, Y Thakur, K Saatchi, ... Contrast Media & Molecular Imaging 2021, 2021 | 8 | 2021 |
Accuracy of Rhenium-188 SPECT/CT activity quantification for applications in radionuclide therapy using clinical reconstruction methods PL Esquinas, CF Uribe, M Gonzalez, C Rodríguez-Rodríguez, UO Häfeli, ... Physics in Medicine & Biology 62 (16), 6379, 2017 | 8 | 2017 |
A fast and simple dose-calibrator-based quality control test for the radionuclidic purity of cyclotron-produced 99mTc J Tanguay, X Hou, P Esquinas, M Vuckovic, K Buckley, P Schaffer, ... Physics in Medicine & Biology 60 (21), 8229, 2015 | 8 | 2015 |
Characteristics of brems strahlung emissions from radionuclide therapy isotopes CF Unbe, PL Esquinas, H Piwowarska-Bilska, D Pawlak, R Mikolajczak, ... 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS …, 2013 | 5 | 2013 |
Accuracy, reproducibility, and uncertainty analysis of thyroid‐probe‐based activity measurements for determination of dose calibrator settings PL Esquinas, J Tanguay, M Gonzalez, M Vuckovic, ... Medical Physics 43 (12), 6309-6321, 2016 | 4 | 2016 |