Suivre
Gilles Soulez
Gilles Soulez
Professor of Radiology, Université de Montréal
Adresse e-mail validée de ssss.gouv.qc.ca
Titre
Citée par
Citée par
Année
Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised …
International Carotid Stenting Study investigators
The Lancet 375 (9719), 985-997, 2010
15382010
Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system
S Martel, JB Mathieu, O Felfoul, A Chanu, E Aboussouan, S Tamaz, ...
Applied physics letters 90 (11), 2007
4522007
Arterial embolotherapy for upper gastrointestinal hemorrhage: outcome assessment
R Aina, VL Oliva, É Therasse, P Perreault, BT Bui, MP Dufresne, G Soulez
Journal of Vascular and Interventional Radiology 12 (2), 195-200, 2001
3312001
Noninvasive vascular elastography: Theoretical framework
RL Maurice, J Ohayon, Y Frétigny, M Bertrand, G Soulez, G Cloutier
IEEE transactions on medical imaging 23 (2), 164-180, 2004
3252004
Soft-tissue venous malformations in adult patients: imaging and therapeutic issues
J Dubois, G Soulez, VL Oliva, MJ Berthiaume, C Lapierre, E Therasse
Radiographics 21 (6), 1519-1531, 2001
3072001
Contrast-induced nephropathy in patients with chronic kidney disease undergoing computed tomography: a double-blind comparison of iodixanol and iopamidol
BJ Barrett, RW Katzberg, HS Thomsen, N Chen, D Sahani, G Soulez, ...
Investigative radiology 41 (11), 815-821, 2006
3002006
Co-encapsulation of magnetic nanoparticles and doxorubicin into biodegradable microcarriers for deep tissue targeting by vascular MRI navigation
P Pouponneau, JC Leroux, G Soulez, L Gaboury, S Martel
Biomaterials 32 (13), 3481-3486, 2011
2762011
Three-dimensional C-arm cone-beam CT: applications in the interventional suite
MJ Wallace, MD Kuo, C Glaiberman, CA Binkert, RC Orth, G Soulez, ...
Journal of Vascular and Interventional Radiology 19 (6), 799-813, 2008
2282008
A new method using Raman spectroscopy for in vivo targeted brain cancer tissue biopsy
J Desroches, M Jermyn, M Pinto, F Picot, MA Tremblay, S Obaid, E Marple, ...
Scientific reports 8 (1), 1792, 2018
2042018
Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributions
MHR Cardinal, J Meunier, G Soulez, RL Maurice, É Therasse, G Cloutier
IEEE transactions on medical imaging 25 (5), 590-601, 2006
1972006
Segmentation in Ultrasonic B-Mode Images of Healthy Carotid Arteries Using Mixtures of Nakagami Distributions and Stochastic Optimization
F Destrempes, J Meunier, MF Giroux, G Soulez, G Cloutier
IEEE Transactions on Medical Imaging 28 (2), 215-229, 2008
1872008
Noninvasive vascular elastography: toward a complementary characterization tool of atherosclerosis in carotid arteries
C Schmitt, G Soulez, RL Maurice, MF Giroux, G Cloutier
Ultrasound in medicine & biology 33 (12), 1841-1858, 2007
1612007
Endovascular proximal forearm arteriovenous fistula for hemodialysis access: results of the prospective, multicenter Novel Endovascular Access Trial (NEAT)
CE Lok, DK Rajan, J Clement, M Kiaii, R Sidhu, K Thomson, G Buldo, ...
American Journal of Kidney Diseases 70 (4), 486-497, 2017
1402017
Imaging of renovascular hypertension: respective values of renal scintigraphy, renal Doppler US, and MR angiography
G Soulez, VL Oliva, S Turpin, R Lambert, V Nicolet, E Therasse
Radiographics 20 (5), 1355-1368, 2000
1352000
Effects of insulin glargine and liraglutide therapy on liver fat as measured by magnetic resonance in patients with type 2 diabetes: a randomized trial
AN Tang, R Rabasa-Lhoret, H Castel, C Wartelle-Bladou, G Gilbert, ...
Diabetes care 38 (7), 1339-1346, 2015
1302015
Treatment of renal angioplasty failure by percutaneous renal artery stenting with Palmaz stents: midterm technical and clinical results.
C Boisclair, E Therasse, VL Oliva, G Soulez, BT Bui, S Querin, P Robillard
AJR. American journal of roentgenology 168 (1), 245-251, 1997
1291997
Automatic multi-dimensional intravascular ultrasound image segmentation method
G Cloutier, MH Roy-Cardinal, J Meunier, G Soulez, E Therasse
US Patent 7,925,064, 2011
1132011
Segmentation of plaques in sequences of ultrasonic B-mode images of carotid arteries based on motion estimation and a Bayesian model
F Destrempes, J Meunier, MF Giroux, G Soulez, G Cloutier
IEEE Transactions on Biomedical Engineering 58 (8), 2202-2211, 2011
1122011
The Jonas study: evaluation of the retrievability of the Cordis OptEase inferior vena cava filter
VL Oliva, F Szatmari, MF Giroux, BK Flemming, SA Cohen, G Soulez
Journal of vascular and interventional radiology 16 (11), 1439-1445, 2005
1052005
MRI systems as a mean of propulsion for a microdevice in blood vessels
JB Mathieu, S Martel, LH Yahia, G Soulez, G Beaudoin
Proceedings of the 25th Annual International Conference of the IEEE …, 2003
1042003
Le système ne peut pas réaliser cette opération maintenant. Veuillez réessayer plus tard.
Articles 1–20