Follow
Marek Maryanski
Marek Maryanski
President and Director of R&D at MGS Research Inc
Verified email at mgsresearch.com
Title
Cited by
Cited by
Year
NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI
MJ Maryanski, JC Gore, RP Kennan, RJ Schulz
Magnetic resonance imaging 11 (2), 253-258, 1993
6541993
Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter
MJ Maryanski, RJ Schulz, GS Ibbott, JC Gatenby, J Xie, D Horton, ...
Physics in Medicine & Biology 39 (9), 1437, 1994
5571994
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner
JC Gore, M Ranade, MJ Maryanski, RJ Schulz
Physics in Medicine & Biology 41 (12), 2695, 1996
4101996
Radiation therapy dosimetry using magnetic resonance imaging of polymer gels
MJ Maryanski, GS Ibbott, P Eastman, RJ Schulz, JC Gore
Medical physics 23 (5), 699-705, 1996
3671996
Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: II. Optical properties of the BANG polymer gel
MJ Maryanski, YZ Zastavker, JC Gore
Physics in Medicine & Biology 41 (12), 2705, 1996
2871996
Characterisation of PRESAGE™: A new 3-D radiochromic solid polymer dosemeter for ionising radiation
J Adamovics, MJ Maryanski
Radiation protection dosimetry 120 (1-4), 107-112, 2006
2422006
Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters
GS Ibbott, MJ Maryanski, P Eastman, SD Holcomb, Y Zhang, RG Avison, ...
International Journal of Radiation Oncology* Biology* Physics 38 (5), 1097-1103, 1997
2111997
Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter
MJ Maryanski, C Audet, JC Gore
Physics in Medicine & Biology 42 (2), 303, 1997
1821997
Performance of a commercial optical CT scanner and polymer gel dosimeters for 3‐D dose verification: optical CT scanning of polymer gel
Y Xu, CS Wuu, MJ Maryanski
Medical physics 31 (11), 3024-3033, 2004
1122004
The effects of cross-link density and chemical exchange on magnetization transfer in polyacrylamide gels
RP Kennan, KA Richardson, J Zhong, MJ Maryanski, JC Gore
Journal of Magnetic Resonance, Series B 110 (3), 267-277, 1996
1001996
Initial evaluation of commercial optical CT‐based 3D gel dosimeter
KTS Islam, JF Dempsey, MK Ranade, MJ Maryanski, DA Low
Medical Physics 30 (8), 2159-2168, 2003
862003
A new approach to radiochromic three-dimensional dosimetry-polyurethane
J Adamovics, MJ Maryanski
Journal of Physics: Conference Series 3 (1), 172, 2004
732004
Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy
OA Zeidan, SI Sriprisan, O Lopatiuk‐Tirpak, PA Kupelian, SL Meeks, ...
Medical Physics 37 (5), 2145-2152, 2010
702010
Image registration of BANGŪ gel dose maps for quantitative dosimetry verification
SL Meeks, FJ Bova, MJ Maryanski, LA Kendrick, MK Ranade, JM Buatti, ...
International Journal of Radiation Oncology* Biology* Physics 43 (5), 1135-1141, 1999
701999
In vivo measurement of cortical bone lead using polarized x rays
L Wielopolski, JF Rosen, DN Slatkin, R Zhang, JA Kalef‐Ezra, ...
Medical physics 16 (4), 521-528, 1989
701989
The role of specific side groups and pH in magnetization transfer in polymers
DF Gochberg, RP Kennan, MJ Maryanski, JC Gore
Journal of magnetic resonance 131 (2), 191-198, 1998
661998
Dosimetry study of Re‐188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser‐beam optical CT scanner
CS Wuu, P Schiff, MJ Maryanski, T Liu, S Borzillary, J Weinberger
Medical Physics 30 (2), 132-137, 2003
602003
New 3D radiochromic solid polymer dosimeter from leuco dyes and a transparent polymeric matrix
J Adamovics, MJ Maryanski
Medical Physics 30 (6), 1349-1349, 2003
592003
Assessment of the accuracy of stereotactic radiosurgery using Fricke‐infused gels and MRI
RJ Schulz, MJ Maryanski, GS Ibbott, JE Bond
Medical physics 20 (6), 1731-1734, 1993
521993
Three-dimensional detection, dosimetry and imaging of an energy field by formation of a polymer in a gel
M Maryanski, J Gore, R Schulz
US Patent 5,321,357, 1994
491994
The system can't perform the operation now. Try again later.
Articles 1–20