Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging Y Yang, YC Tai, S Siegel, DF Newport, B Bai, Q Li, RM Leahy, SR Cherry Physics in medicine & biology 49 (12), 2527, 2004 | 209 | 2004 |
Tumor quantification in clinical positron emission tomography B Bai, J Bading, PS Conti Theranostics 3 (10), 787, 2013 | 151 | 2013 |
Magnetic resonance-guided positron emission tomography image reconstruction B Bai, Q Li, RM Leahy Seminars in nuclear medicine 43 (1), 30-44, 2013 | 125 | 2013 |
Model-based normalization for iterative 3D PET image reconstruction B Bai, Q Li, CH Holdsworth, E Asma, YC Tai, A Chatziioannou, RM Leahy Physics in medicine & biology 47 (15), 2773, 2002 | 101 | 2002 |
Positron range modeling for statistical PET image reconstruction B Bai, A Ruangma, R Laforest, YC Tai, RM Leahy 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No …, 2003 | 91 | 2003 |
NEMA NU-4 performance evaluation of PETbox4, a high sensitivity dedicated PET preclinical tomograph Z Gu, R Taschereau, NT Vu, H Wang, DL Prout, RW Silverman, B Bai, ... Physics in Medicine & Biology 58 (11), 3791, 2013 | 77 | 2013 |
Patlak image estimation from dual time-point list-mode PET data W Zhu, Q Li, B Bai, PS Conti, RM Leahy IEEE transactions on medical imaging 33 (4), 913-924, 2014 | 66 | 2014 |
Three-dimensional maximum a posteriori (MAP) imaging with radiopharmaceuticals labeled with three Cu radionuclides A Ruangma, B Bai, JS Lewis, X Sun, MJ Welch, R Leahy, R Laforest Nuclear medicine and biology 33 (2), 217-226, 2006 | 46 | 2006 |
The effect of edge artifacts on quantification of positron emission tomography B Bai, PD Esser IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2263-2266, 2010 | 42 | 2010 |
Evaluation of MAP image reconstruction with positron range modeling for 3D PET B Bai, R Laforest, AM Smith, RM Leahy IEEE Nuclear Science Symposium Conference Record, 2005 5, 2686-2689, 2005 | 41 | 2005 |
Iterative image reconstruction using inverse Fourier rebinning for fully 3-D PET S Cho, Q Li, S Ahn, B Bai, RM Leahy IEEE Transactions on Medical Imaging 26 (5), 745-756, 2007 | 35 | 2007 |
Fast 3D iterative reconstruction of PET images using PC graphics hardware B Bai, AM Smith 2006 IEEE Nuclear Science Symposium Conference Record 5, 2787-2790, 2006 | 32 | 2006 |
Modeling of the point spread function by numerical calculations in single-pinhole and multipinhole SPECT reconstruction B Feng, M Chen, B Bai, AM Smith, DW Austin, RA Mintzer, D Osborne, ... IEEE Transactions on Nuclear Science 57 (1), 173-180, 2010 | 31 | 2010 |
In Vivo Brain Imaging, Biodistribution, and Radiation Dosimetry Estimation of [11C]Celecoxib, a COX-2 PET Ligand, in Nonhuman Primates JSD Kumar, B Bai, F Zanderigo, C DeLorenzo, J Prabhakaran, RV Parsey, ... Molecules 23 (8), 1929, 2018 | 27 | 2018 |
MAP reconstruction for Fourier rebinned TOF-PET data B Bai, Y Lin, W Zhu, R Ren, Q Li, M Dahlbom, F DiFilippo, RM Leahy Physics in Medicine & Biology 59 (4), 925, 2014 | 19 | 2014 |
A new pulse pileup rejection method based on position shift identification Z Gu, DL Prout, R Taschereau, B Bai, AF Chatziioannou IEEE transactions on nuclear science 63 (1), 22-29, 2016 | 13 | 2016 |
Direct patlak estimation from list-mode PET data RM Leahy, W Zhu, Q Li, B Bai, PS Conti US Patent 10,022,097, 2018 | 12 | 2018 |
Direct estimation from list-mode data for reversible tracers using graphical modeling W Zhu, N Guo, B Bai, PS Conti, RM Leahy, Q Li 2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 1204-1207, 2015 | 12 | 2015 |
Locally weighted total variation denoising for ringing artifact suppression in pet reconstruction using PSF modeling A Mikhno, ED Angelini, B Bai, AF Laine 2013 IEEE 10th International Symposium on Biomedical Imaging, 1252-1255, 2013 | 11 | 2013 |
Count independent resolution and its calibration Q Li, B Bai, S Cho, A Smith, R Leahy 10th International Meeting on Fully Three-Dimensional Image Reconstruction …, 2009 | 11 | 2009 |