Magdalena Bazalova-Carter
Magdalena Bazalova-Carter
Assistant Professor and Canada Research Chair in Medical Physics (Tier 2)
Verified email at uvic.ca - Homepage
TitleCited byYear
Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations
M Bazalova, JF Carrier, L Beaulieu, F Verhaegen
Physics in Medicine & Biology 53 (9), 2439, 2008
1792008
Correction of CT artifacts and its influence on Monte Carlo dose calculations
M Bazalova, L Beaulieu, S Palefsky, F Verhaegen
Medical physics 34 (6Part1), 2119-2132, 2007
1252007
Investigation of X-ray fluorescence computed tomography (XFCT) and K-edge imaging
M Bazalova, Y Kuang, G Pratx, L Xing
IEEE Transactions on Medical Imaging 31 (8), 1620-1627, 2012
702012
Monte Carlo simulation of a computed tomography x-ray tube
M Bazalova, F Verhaegen
Physics in Medicine & Biology 52 (19), 5945, 2007
702007
Tissue segmentation in Monte Carlo treatment planning: a simulation study using dual-energy CT images
M Bazalova, JF Carrier, L Beaulieu, F Verhaegen
Radiotherapy and Oncology 86 (1), 93-98, 2008
662008
First demonstration of multiplexed x-ray fluorescence computed tomography (XFCT) imaging
Y Kuang, G Pratx, M Bazalova, B Meng, J Qian, L Xing
IEEE transactions on medical imaging 32 (2), 262-267, 2012
602012
The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy
M Bazalova, EE Graves
Medical physics 38 (6Part1), 3039-3049, 2011
472011
Spectroscopic characterization of a novel electronic brachytherapy system
D Liu, E Poon, M Bazalova, B Reniers, M Evans, T Rusch, F Verhaegen
Physics in Medicine & Biology 53 (1), 61, 2007
472007
Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy
M Bazalova, H Zhou, PJ Keall, EE Graves
Medical physics 36 (11), 4991-4999, 2009
412009
X-ray luminescence and x-ray fluorescence computed tomography: new molecular imaging modalities
M Ahmad, G Pratx, M Bazalova, LEI Xing
Ieee Access 2, 1051-1061, 2014
392014
Order of magnitude sensitivity increase in x-ray fluorescence computed tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation
M Ahmad, M Bazalova, L Xiang, L Xing
IEEE transactions on medical imaging 33 (5), 1119-1128, 2014
322014
RECORDS: improved reporting of montE CarlO RaDiation transport studies: report of the AAPM Research Committee Task Group 268
I Sechopoulos, DWO Rogers, M Bazalova‐Carter, WE Bolch, EC Heath, ...
Medical physics 45 (1), e1-e5, 2018
282018
Optimized detector angular configuration increases the sensitivity of x-ray fluorescence computed tomography (XFCT)
M Ahmad, M Bazalova-Carter, R Fahrig, L Xing
IEEE transactions on medical imaging 34 (5), 1140-1147, 2014
242014
L-shell x-ray fluorescence computed tomography (XFCT) imaging of Cisplatin
M Bazalova, M Ahmad, G Pratx, L Xing
Physics in Medicine & Biology 59 (1), 219, 2013
242013
Development of XFCT imaging strategy for monitoring the spatial distribution of platinum‐based chemodrugs: Instrumentation and phantom validation
Y Kuang, G Pratx, M Bazalova, J Qian, B Meng, L Xing
Medical physics 40 (3), 030701, 2013
242013
Molecular magnetic resonance imaging of tumor response to therapy
AJ Shuhendler, D Ye, KD Brewer, M Bazalova-Carter, KH Lee, P Kempen, ...
Scientific reports 5, 14759, 2015
232015
Modality comparison for small animal radiotherapy: a simulation study
M Bazalova, G Nelson, JM Noll, EE Graves
Medical physics 41 (1), 011710, 2014
222014
Treatment planning for radiotherapy with very high‐energy electron beams and comparison of VHEE and VMAT plans
M Bazalova‐Carter, B Qu, B Palma, B Hårdemark, E Hynning, C Jensen, ...
Medical physics 42 (5), 2615-2625, 2015
202015
Investigation of the effects of treatment planning variables in small animal radiotherapy dose distributions
AR Motomura, M Bazalova, H Zhou, PJ Keall, EE Graves
Medical physics 37 (2), 590-599, 2010
202010
Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability
SN Chen, M Gauthier, M Bazalova-Carter, S Bolanos, S Glenzer, ...
Review of Scientific Instruments 87 (7), 073301, 2016
152016
The system can't perform the operation now. Try again later.
Articles 1–20