A spatial coherence approach to minimum variance beamforming for plane-wave compounding
NQ Nguyen, RW Prager
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 65 …, 2018
602018
High-resolution ultrasound imaging with unified pixel-based beamforming
NQ Nguyen, RW Prager
Medical Imaging, IEEE Transactions on 35 (1), 98-108, 2016
502016
Minimum variance approaches to ultrasound pixel-based beamforming
NQ Nguyen, RW Prager
IEEE Transactions on Medical Imaging 36 (2), 374-384, 2016
302016
Breast ultrasound waveform tomography: Using both transmission and reflection data, and numerical virtual point sources
L Huang, Y Lin, Z Zhang, Y Labyed, S Tan, NQ Nguyen, KM Hanson, ...
Medical Imaging 2014: Ultrasonic Imaging and Tomography 9040, 187-198, 2014
282014
Optimal beamforming in ultrasound using the ideal observer
CK Abbey, NQ Nguyen, MF Insana
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 57 …, 2010
232010
Objective assessment of sonographic quality I: Task information
NQ Nguyen, CK Abbey, MF Insana
IEEE transactions on medical imaging 32 (4), 683-690, 2012
222012
Effects of frequency and bandwidth on diagnostic information transfer in ultrasonic B-mode imaging
CK Abbey, NQ Nguyen, MF Insana
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 59 …, 2012
222012
Ultrasound-guided targeted biopsies of CT-based radiomic tumour habitats: technical development and initial experience in metastatic ovarian cancer
L Beer, P Martin-Gonzalez, M Delgado-Ortet, M Reinius, L Rundo, ...
European radiology 31, 3765-3772, 2021
212021
An adaptive filter to approximate the Bayesian strategy for sonographic beamforming
NQ Nguyen, CK Abbey, MF Insana
IEEE transactions on medical imaging 30 (1), 28-37, 2010
212010
Objective assessment of sonographic: Quality II acquisition information spectrum
NQ Nguyen, CK Abbey, MF Insana
IEEE transactions on medical imaging 32 (4), 691-698, 2012
202012
Improved ultrasound image quality with pixel-based beamforming using a Wiener-filter and a SNR-dependent coherence factor
HW Xie, H Guo, GQ Zhou, NQ Nguyen, RW Prager
Ultrasonics 119, 106594, 2022
162022
Ultrasound pixel-based beamforming with phase alignments of focused beams
NQ Nguyen, RW Prager
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 64 …, 2017
142017
Ultrasound bent-ray tomography using both transmission and reflection data
NQ Nguyen, L Huang
Medical Imaging 2014: Ultrasonic Imaging and Tomography 9040, 172-179, 2014
122014
Minimum variance beamformers for coherent plane-wave compounding
NQ Nguyen, RW Prager
Medical Imaging 2017: Ultrasonic Imaging and Tomography 10139, 254-263, 2017
72017
Detectability index describes the information conveyed by sonographic images
NQ Nguyen, CK Abbey, MF Insana
2011 IEEE International Ultrasonics Symposium, 680-683, 2011
62011
Photoacoustic–ultrasonic dual-mode microscopy with local speed-of-sound estimation
W Chen, C Tao, NQ Nguyen, RW Prager, X Liu
Optics Letters 45 (14), 3840-3843, 2020
52020
Tomographic reconstruction of the pulse-echo spatiotemporal impulse response
NQ Nguyen, CK Abbey, RD Yapp, MF Insana
Medical Imaging 2010: Ultrasonic Imaging, Tomography, and Therapy 7629, 134-144, 2010
42010
Improvements to ultrasonic beamformer design and implementation derived from the task-based analytical framework
NQ Nguyen, RW Prager, MF Insana
The Journal of the Acoustical Society of America 141 (6), 4427-4437, 2017
32017
A task-based analytical framework for ultrasonic beamformer comparison
NQ Nguyen, RW Prager, MF Insana
The Journal of the Acoustical Society of America 140 (2), 1048-1059, 2016
32016
Robustness of Wiener filtering as an approximation to the Bayesian observer stragegy
NQ Nguyen, CK Abbey, MF Insana
2010 IEEE International Ultrasonics Symposium, 995-998, 2010
32010