A new contribution to the finite line-source model for geothermal boreholes L Lamarche, B Beauchamp Energy and Buildings 39 (2), 188-198, 2007 | 518 | 2007 |
A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems L Lamarche, S Kajl, B Beauchamp Geothermics 39 (2), 187-200, 2010 | 422 | 2010 |
New solutions for the short-time analysis of geothermal vertical boreholes L Lamarche, B Beauchamp International Journal of Heat and Mass Transfer 50 (7-8), 1408-1419, 2007 | 236 | 2007 |
A new modeling approach for improved ground temperature profile determination M Badache, P Eslami-Nejad, M Ouzzane, Z Aidoun, L Lamarche Renewable Energy 85, 436-444, 2016 | 106 | 2016 |
A fast algorithm for the hourly simulations of ground-source heat pumps using arbitrary response factors L Lamarche Renewable Energy 34 (10), 2252-2258, 2009 | 70 | 2009 |
Simulation of thermal response tests in a layered subsurface J Raymond, L Lamarche Applied energy 109, 293-301, 2013 | 61 | 2013 |
A comparative performance study of a direct expansion geothermal evaporator using R410A and R407C as refrigerant alternatives to R22 JLC Fannou, C Rousseau, L Lamarche, S Kajl Applied Thermal Engineering 82, 306-317, 2015 | 59 | 2015 |
Analytical g-function for inclined boreholes in ground-source heat pump systems L Lamarche Geothermics 40 (4), 241-249, 2011 | 56 | 2011 |
Modeling of a direct expansion geothermal heat pump using artificial neural networks JLC Fannou, C Rousseau, L Lamarche, S Kajl Energy and Buildings 81, 381-390, 2014 | 53 | 2014 |
Short-term behavior of classical analytic solutions for the design of ground-source heat pumps L Lamarche Renewable energy 57, 171-180, 2013 | 53 | 2013 |
Field demonstration of a first thermal response test with a low power source J Raymond, L Lamarche, M Malo Applied energy 147, 30-39, 2015 | 51 | 2015 |
Thermal modeling of evacuated tube solar air collectors PL Paradis, DR Rousse, S Hallé, L Lamarche, G Quesada Solar energy 115, 708-721, 2015 | 49 | 2015 |
Short-time analysis of vertical boreholes, new analytic solutions and choice of equivalent radius L Lamarche International journal of heat and mass transfer 91, 800-807, 2015 | 48 | 2015 |
Analysis of the convective heat exchange effect on the undisturbed ground temperature M Ouzzane, P Eslami-Nejad, Z Aidoun, L Lamarche Solar Energy 108, 340-347, 2014 | 43 | 2014 |
Experimental analysis of a direct expansion geothermal heat pump in heating mode JL Fannou, C Rousseau, L Lamarche, K Stanislaw Energy and Buildings 75, 290-300, 2014 | 43 | 2014 |
Numerical parametric study of a new earth-air heat exchanger configuration designed for hot and arid climates N Benrachi, M Ouzzane, A Smaili, L Lamarche, M Badache, W Maref International journal of green energy 17 (2), 115-126, 2020 | 41 | 2020 |
Evaluation of building energy consumption based on fuzzy logic and neural networks applications S Kajl, MA Roberge, L Lamarche, P Malinowski Proceedings of CLIMA 2000 conference, 264-274, 1997 | 40 | 1997 |
Development and numerical validation of a novel thermal response test with a low power source J Raymond, L Lamarche Geothermics 51, 434-444, 2014 | 38 | 2014 |
A fast algorithm for the simulation of GCHP systems. L Lamarche, B Beauchamp ASHRAE Transactions 113 (1), 470-477, 2007 | 38 | 2007 |
Horizontal ground heat exchangers modelling L Lamarche Applied thermal engineering 155, 534-545, 2019 | 37 | 2019 |