Current ultrafiltration techniques before, during and after pediatric cardiopulmonary bypass procedures S Wang, D Palanzo, A Ündar Perfusion 27 (5), 438-446, 2012 | 71 | 2012 |
Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults Y Guan, T Karkhanis, S Wang, A Rider, SC Koenig, MS Slaughter, ... Artificial Organs 34 (7), 529-536, 2010 | 61 | 2010 |
Laboratory evaluation of hemolysis and systemic inflammatory response in neonatal nonpulsatile and pulsatile extracorporeal life support systems S Wang, C Krawiec, S Patel, AR Kunselman, J Song, F Lei, LD Baer, ... Artificial organs 39 (9), 774-781, 2015 | 58 | 2015 |
Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass S Wang, A Ündar The Journal of ExtraCorporeal Technology 40 (4), 249-256, 2008 | 54 | 2008 |
Clinical outcomes of pulsatile and non-pulsatile mode of perfusion N Haines, S Wang, A Ündar, T Alkan, A Akcevin The Journal of Extra-corporeal Technology 41 (1), P26, 2009 | 52 | 2009 |
Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children KN Win, S Wang, A Ündar ASAIO Journal 54 (5), 486-490, 2008 | 49 | 2008 |
Impact of high mechanical shear stress and oxygenator membrane surface on blood damage relevant to thrombosis and bleeding in a pediatric ECMO circuit W Sun, S Wang, Z Chen, J Zhang, T Li, K Arias, BP Griffith, ZJ Wu Artificial organs 44 (7), 717-726, 2020 | 47 | 2020 |
Ventilatory chemoresponsiveness, narcolepsy–cataplexy and human leukocyte antigen DQB1* 0602 status F Han, E Mignot, YC Wei, SX Dong, J Li, L Lin, P An, LH Wang, JS Wang, ... European Respiratory Journal 36 (3), 577-583, 2010 | 45 | 2010 |
“Stolen” blood flow: effect of an open arterial filter purge line in a simulated neonatal CPB model S Wang, A Miller, JL Myers, A Undar ASAIO Journal 54 (4), 432-435, 2008 | 45 | 2008 |
Current techniques and outcomes in extracorporeal life support JB Clark, S Wang, DA Palanzo, R Wise, LD Baer, C Brehm, A Ündar Artificial organs 39 (11), 926-930, 2015 | 41 | 2015 |
Choosing a pump for extracorporeal membrane oxygenation in the USA. DA Palanzo, LD Baer, A El‐Banayosy, S Wang, A Ündar, WE Pae Artificial organs 38 (1), 2014 | 41 | 2014 |
Device-induced hemostatic disorders in mechanically assisted circulation S Wang, BP Griffith, ZJ Wu Clinical and Applied Thrombosis/Hemostasis 27, 1076029620982374, 2021 | 40 | 2021 |
Novel pulsatile diagonal pump for pediatric extracorporeal life support system S Wang, AR Kunselman, A Ündar Artificial organs 37 (1), 37-47, 2013 | 40 | 2013 |
Comparison of two types of neonatal extracorporeal life support systems with pulsatile and nonpulsatile flow N Haines, S Wang, JL Myers, A Ündar Artificial organs 33 (11), 958-966, 2009 | 40 | 2009 |
Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model S Wang, L Baer, AR Kunselman, JL Myers, A Ündar ASAIO Journal 54 (4), 416-422, 2008 | 37 | 2008 |
In vivo hemodynamic performance evaluation of novel electrocardiogram‐synchronized pulsatile and nonpulsatile extracorporeal life support systems in an adult swine model S Wang, JM Izer, JB Clark, S Patel, L Pauliks, AR Kunselman, D Leach, ... Artificial organs 39 (7), E90-E101, 2015 | 36 | 2015 |
In vitro hemodynamic evaluation of a novel pulsatile extracorporeal life support system: impact of perfusion modes and circuit components on energy loss S Wang, AR Kunselman, JB Clark, A Ündar Artificial organs 39 (1), 59-66, 2015 | 35 | 2015 |
Clinical real‐time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass S Wang, K Woitas, JB Clark, JL Myers, A Ündar Artificial Organs 33 (11), 1026-1030, 2009 | 34 | 2009 |
Comparison with parametric optimization in credit card fraud detection MFA Gadi, X Wang, AP do Lago 2008 Seventh International Conference on Machine Learning and Applications …, 2008 | 34 | 2008 |
Quantification of pressure-flow waveforms and selection of components for the pulsatile extracorporeal circuit S Wang, N Haines, A Ündar The Journal of Extra-corporeal Technology 41 (1), P20, 2009 | 33 | 2009 |