Revised histopathological consensus classification of joint implant related pathology V Krenn, L Morawietz, G Perino, H Kienapfel, R Ascherl, GJ Hassenpflug, ... Pathology-Research and Practice 210 (12), 779-786, 2014 | 310 | 2014 |
CD4+CD25+/highCD127low/- regulatory T cells are enriched in rheumatoid arthritis and osteoarthritis joints—analysis of frequency and phenotype in synovial … B Moradi, P Schnatzer, S Hagmann, N Rosshirt, T Gotterbarm, JP Kretzer, ... Arthritis research & therapy 16, 1-13, 2014 | 151 | 2014 |
What’s next? Alternative materials for articulation in total joint replacement R Sonntag, J Reinders, JP Kretzer Acta biomaterialia 8 (7), 2434-2441, 2012 | 144 | 2012 |
Characterization of the running-in period in total hip resurfacing arthroplasty: an in vivo and in vitro metal ion analysis C Heisel, N Streich, M Krachler, E Jakubowitz, JP Kretzer JBJS 90 (Supplement_3), 125-133, 2008 | 120 | 2008 |
Metal release and corrosion effects of modular neck total hip arthroplasty JP Kretzer, E Jakubowitz, M Krachler, M Thomsen, C Heisel International orthopaedics 33, 1531-1536, 2009 | 114 | 2009 |
Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study JP Kretzer, E Jakubowitz, J Reinders, E Lietz, B Moradi, K Hofmann, ... Acta Biomaterialia 7 (2), 710-715, 2011 | 94 | 2011 |
Do short-stemmed-prostheses induce periprosthetic fractures earlier than standard hip stems? A biomechanical ex-vivo study of two different stem designs E Jakubowitz, JB Seeger, C Lee, C Heisel, JP Kretzer, MN Thomsen Archives of Orthopaedic and trauma surgery 129, 849-855, 2009 | 86 | 2009 |
Wear in total knee arthroplasty—just a question of polyethylene? Metal ion release in total knee arthroplasty JP Kretzer, J Reinders, R Sonntag, S Hagmann, M Streit, S Jeager, ... International orthopaedics 38, 335-340, 2014 | 82 | 2014 |
Fatigue performance of medical Ti6Al4V alloy after mechanical surface treatments R Sonntag, J Reinders, J Gibmeier, JP Kretzer PLoS One 10 (3), e0121963, 2015 | 65 | 2015 |
Ten different hip resurfacing systems: biomechanical analysis of design and material properties C Heisel, JA Kleinhans, M Menge, JP Kretzer International orthopaedics 33, 939-943, 2009 | 63 | 2009 |
Mobile-bearing lateral unicompartmental knee replacement with the Oxford domed tibial component: an independent series MR Streit, T Walker, T Bruckner, C Merle, JP Kretzer, M Clarius, ... The Journal of Bone & Joint Surgery British Volume 94 (10), 1356-1361, 2012 | 62 | 2012 |
Primary stability of the Fitmore® stem: biomechanical comparison W Pepke, J Nadorf, V Ewerbeck, MR Streit, S Kinkel, T Gotterbarm, ... International orthopaedics 38, 483-488, 2014 | 55 | 2014 |
Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger MM Innmann, T Gotterbarm, JP Kretzer, C Merle, V Ewerbeck, S Weiss, ... International orthopaedics 38, 929-934, 2014 | 54 | 2014 |
Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up MW Maier, MR Streit, MM Innmann, M Krüger, J Nadorf, JP Kretzer, ... BMC musculoskeletal disorders 16, 1-9, 2015 | 53 | 2015 |
Effect of joint laxity on polyethylene wear in total knee replacement JP Kretzer, E Jakubowitz, R Sonntag, K Hofmann, C Heisel, M Thomsen Journal of biomechanics 43 (6), 1092-1096, 2010 | 53 | 2010 |
Same same but different? 12/14 stem and head tapers in total hip arthroplasty U Mueller, S Braun, S Schroeder, R Sonntag, JP Kretzer The Journal of arthroplasty 32 (10), 3191-3199, 2017 | 51 | 2017 |
Primary rotational stability of cylindrical and conical revision hip stems as a function of femoral bone defects: an in vitro comparison E Jakubowitz, RG Bitsch, C Heisel, C Lee, JP Kretzer, MN Thomsen Journal of biomechanics 41 (14), 3078-3084, 2008 | 49 | 2008 |
Minimally invasive Oxford medial unicompartmental knee arthroplasty in young patients MR Streit, J Streit, T Walker, T Bruckner, J Philippe Kretzer, V Ewerbeck, ... Knee Surgery, Sports Traumatology, Arthroscopy 25, 660-668, 2017 | 48 | 2017 |
Validation of ultratrace analysis of Co, Cr, Mo and Ni in whole blood, serum and urine using ICP-SMS M Krachler, C Heisel, JP Kretzer Journal of Analytical Atomic Spectrometry 24 (5), 605-610, 2009 | 47 | 2009 |
Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placement S Rues, M Schmitter, S Kappel, R Sonntag, JP Kretzer, J Nadorf Clinical oral investigations 25, 1265-1272, 2021 | 46 | 2021 |