Follow
Jean-Philippe Luyckx
Jean-Philippe Luyckx
European Centre for Knee Research, Smith & Nephew
No verified email
Title
Cited by
Cited by
Year
Cementing the tibial component in total knee arthroplasty: which technique is the best?
J Vanlommel, JP Luyckx, L Labey, B Innocenti, R De Corte, J Bellemans
The Journal of arthroplasty 26 (3), 492-496, 2011
1542011
The influence of malrotation of the femoral component in total knee replacement on the mechanics of patellofemoral contact during gait: an in vitro biomechanical study
C Verlinden, P Uvin, L Labey, JP Luyckx, J Bellemans, H Vandenneucker
The Journal of Bone & Joint Surgery British Volume 92 (5), 737-742, 2010
832010
Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs
N Arnout, L Vanlommel, J Vanlommel, JP Luyckx, L Labey, B Innocenti, ...
Knee surgery, sports traumatology, arthroscopy 23, 3343-3353, 2015
732015
Femoral component loosening in high-flexion total knee replacement: an in vitro comparison of high-flexion versus conventional designs.
P Bollars, JP Luyckx, B Innocenti, L Labey, J Victor, J Bellemans
The Journal of Bone and Joint Surgery - British Volume 93 (10), 1355-61, 2011
482011
Torsional injuries of the lower limb: an analysis of the frictional torque between different types of football turf and the shoe outsole
K Smeets, P Jacobs, R Hertogs, JP Luyckx, B Innocenti, K Corten, ...
British journal of sports medicine 46 (15), 1078-1083, 2012
462012
The influence of malrotation and femoral component material on patellofemoral wear during gait
J Vanbiervliet, J Bellemans, C Verlinden, JP Luyckx, L Labey, B Innocenti, ...
Journal of Bone and Joint Surgery - British Volume 93 (10), 1348-54, 2011
262011
Mean tensile strength of the PCL in TKA depends on the preservation of the tibial insertion site
N Van Opstal, H Feyen, JP Luyckx, J Bellemans
Knee Surgery, Sports Traumatology, Arthroscopy 24, 273-278, 2016
172016
Articulation of native cartilage against different femoral component materials. Oxidized zirconium damages cartilage less than cobalt-chrome
J Vanlommel, R De Corte, JP Luyckx, M Anderson, L Labey, J Bellemans
The Journal of Arthroplasty 32 (1), 256-262, 2017
162017
Comparing cementing techniques in total knee arthroplasty: an in vitro study
T Wetzels, J van Erp, RW Brouwer, SK Bulstra, JJAM van Raay
The journal of knee surgery 32 (09), 886-890, 2019
112019
Iatrogenic surface damage during femoral component impaction in total knee arthroplasty
J Vanlommel, AJ Porteous, MA Hassaballa, JP Luyckx, J Bellemans
The Knee 17 (1), 43-47, 2010
52010
Isolated tibial component failure in total knee arthroplasty: a case series evaluating inflammatory response versus mechanical failure
SS Yokhana, C Bergum, W Ren, DC Markel
The Journal of Knee Surgery 32 (07), 659-666, 2019
42019
The influence of implant position on final clinical outcome and gait analysis after total knee arthroplasty
J Jabłoński, M Sibiński, M Polguj, J Kowalczewski, D Marczak, Ł Faflik, ...
The Journal of Knee Surgery 32 (09), 891-896, 2019
32019
Post-cam contact mechanics in posterior stabilized TKA designs
N Arnout, J Vanlommel, L Vanlommel, JP Luyckx, L Labey, J Victor, ...
Knee Surgery, Sports Traumatology, Arthroscopy 18 (1), 2010
12010
The Influence of Malrotation and Material of the Femoral Component on Patellofemoral Contact Mechanics and Wear During Gait
JP Luyckx, C Verlinden, J Vanbiervliet, L Labey, B Innocenti, J Leuven, ...
Orthopaedic Proceedings 94 (SUPP_XL), 99-99, 2012
2012
How does malrotation and material of the femoral component in TKA influence patellofemoral contact mechanics and wear during gait?
JP Luyckx, C Verlinden, J Vanbiervliet, L Labey, H Vandenneucker, ...
Knee Surgery, Sports Traumatology, Arthroscopy 20 (1), 2012
2012
Femoral component loosening in high-flexion total knee replacement: An in vitro comparison of high-flexion versus conventional designs (vol 93, pg 1355, 2011)
P Bollers, JP Luyckx, B Innocenti, L Labey, J Victor, J Bellemans
Journal of Bone and Joint Surgery, British Volume 93 (12), 1679-1679, 2011
2011
A device to test the rotational and translational interaction of shoe-surface systems
K Denis, B Peeters, S Van Woensel, B Innocenti, JP Luyckx, K Smeets, ...
Proceedings of the 10th National Day of Biomedical Engineering, 2011
2011
In-vitro femoral component loosening of TKA: comparison of high-flex and conventional PS designs
P Bollars, JP Luyckx, B Innocenti, L Labey, J Victor, J Bellemans
Journal of Bone and Joint Surgery - British Volume, Orthopaedic Proceedings …, 2011
2011
Development of a device to test the rotational and translational interaction of shoe-surface systems
K Denis, B Peeters, S Van Woensel, B Innocenti, JP Luyckx, K Smeets, ...
ISB 2011 Proceedings, 2011
2011
In-vitro testing of loosening of the femoral component in comparison of several high-flex and conventional PS designs
P Bollars, JP Luyckx, B Innocenti, L Labey, J Victor, J Bellemans
Knee Surgery, Sports Traumatology, Arthroscopy 18 (1), 2010
2010
The system can't perform the operation now. Try again later.
Articles 1–20