Choon-Sik Jhun
Title
Cited by
Cited by
Year
A computationally efficient formal optimization of regional myocardial contractility in a sheep with left ventricular aneurysm
K Sun, N Stander, CS Jhun, Z Zhang, T Suzuki, GY Wang, M Saeed, ...
912009
Mechanical properties of surgical glues used in aortic root replacement
AN Azadani, PB Matthews, L Ge, Y Shen, CS Jhun, TS Guy, EE Tseng
The Annals of thoracic surgery 87 (4), 1154-1160, 2009
712009
Comparison of porcine pulmonary and aortic root material properties
PB Matthews, AN Azadani, CS Jhun, L Ge, TS Guy, JM Guccione, ...
The Annals of thoracic surgery 89 (6), 1981-1988, 2010
472010
Planar biaxial mechanical behavior of bioartificial tissues possessing prescribed fiber alignment
CS Jhun, MC Evans, VH Barocas, RT Tranquillo
452009
Effect of adjustable passive constraint on the failing left ventricle: a finite-element model study
CS Jhun, JF Wenk, Z Zhang, ST Wall, K Sun, HN Sabbah, MB Ratcliffe, ...
The Annals of thoracic surgery 89 (1), 132-137, 2010
262010
Effective ventricular unloading by left ventricular assist device varies with stage of heart failure: cardiac simulator study
CS Jhun, JD Reibson, JP Cysyk
Asaio Journal 57 (5), 407-413, 2011
212011
Stress and exposure time on von Willebrand factor degradation
CS Jhun, C Siedlecki, L Xu, B Lukic, R Newswanger, E Yeager, J Reibson, ...
Artificial organs 43 (2), 199-206, 2019
122019
Determination of Reynolds shear stress level for hemolysis
CS Jhun, MA Stauffer, JD Reibson, EE Yeager, RK Newswanger, ...
ASAIO journal (American Society for Artificial Internal Organs: 1992) 64 (1), 63, 2018
112018
Tesla-based blood pump and its applications
CS Jhun, R Newswanger, J Cysyk, B Lukic, W Weiss, G Rosenberg
Journal of medical devices 7 (4), 2013
112013
Cannula Tip with Integrated Volume Sensor for Rotary Blood Pump Control: Early Stage Development
J Cysyk, R Newswanger, E Popjes, W Pae, CS Jhun, J Izer, W Weiss, ...
ASAIO journal (American Society for Artificial Internal Organs: 1992) 65 (4 …, 2019
102019
Chronic in vivo test of a right heart replacement blood pump for failed Fontan circulation
J Cysyk, JB Clark, R Newswanger, CS Jhun, J Izer, H Finicle, J Reibson, ...
Asaio Journal 65 (6), 593-600, 2019
92019
Acquired von Willebrand syndrome and blood pump design
G Rosenberg, CA Siedlecki, CS Jhun, WJ Weiss, K Manning, S Deutsch, ...
Artificial organs 42 (12), 1119-1124, 2018
92018
Continuous flow left ventricular pump support and its effect on regional left ventricular wall stress: finite element analysis study
CS Jhun, K Sun, JP Cysyk
Medical & biological engineering & computing 52 (12), 1031-1040, 2014
92014
Finite element modeling of the pulmonary autograft at systemic pressure before remodeling
PB Matthews, CS Jhun, S Yaung, AN Azadani, JM Guccione, L Ge, ...
Journal of Heart Valve Disease 20 (1), 45, 2011
92011
Rotary blood pump control using integrated inlet pressure sensor
J Cysyk, CS Jhun, R Newswanger, W Weiss, G Rosenberg
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
82011
Characterization of mechanical behavior of a porcine pulmonary artery strip using a randomized uniaxial stretch and stretch-rate protocol
CS Jhun, JC Criscione
Biomedical engineering online 7 (1), 1-11, 2008
72008
Fiber reorientation in planar biaxial loading of bioartificial tissues possessing prescribed alignment
C Jhun, MC Evans, VH Barocas, RT Tranquillo
Ann. Biomed. Eng., submitted, 2008
52008
In vivo left ventricular geometry and boundary conditions
JF Wenk, CS Jhun, Z Zhang, K Sun, M Burger, D Einstein, M Ratcliffe, ...
Computational Cardiovascular Mechanics, 3-21, 2010
42010
Ventricular contractility and compliance measured during axial flow blood pump support: in vitro study
CS Jhun, JP Cysyk
Artificial organs 38 (4), 309-315, 2014
32014
Fontan circulatory assist device
CS Jhun, R Newswanger, JP Cysyk, M Stauffer, W Weiss, G Rosenberg
Journal of Medical Devices 9 (2), 2015
22015
The system can't perform the operation now. Try again later.
Articles 1–20