Ceyhun Kirimli
Ceyhun Kirimli
Assistant Professor in Acibadem University
Verified email at drexel.edu - Homepage
Title
Cited by
Cited by
Year
Real-time, in situ DNA hybridization detection with attomolar sensitivity without amplification using (pb (Mg1/3Nb2/3) O3) 0.65–(PbTiO3) 0.35 piezoelectric plate sensors
W Wu, CE Kirimli, WH Shih, WY Shih
Biosensors and Bioelectronics 43, 391-399, 2013
162013
DNA hybridization detection with 100 zM sensitivity using piezoelectric plate sensors with an improved noise-reduction algorithm
CE Kirimli, WH Shih, WY Shih
Analyst 139 (11), 2754-2763, 2014
112014
Specific in situ hepatitis B viral double mutation (HBVDM) detection in urine with 60 copies ml− 1 analytical sensitivity in a background of 250-fold wild type without DNA†…
CE Kirimli, WH Shih, WY Shih
Analyst 140 (5), 1590-1598, 2015
82015
Temperature-and flow-enhanced detection specificity of mutated DNA against the wild type with reporter microspheres
CE Kirimli, WH Shih, WY Shih
Analyst 138 (20), 6117-6126, 2013
62013
Amplification-free in situ KRAS point mutation detection at 60 copies per mL in urine in a background of 1000-fold wild type
CE Kirimli, WH Shih, WY Shih
Analyst 141 (4), 1421-1433, 2016
52016
Rapid, label-free genetic detection of enteropathogens in stool without genetic isolation or amplification
S Han, MC Soylu, CE Kirimli, W Wu, B Sen, SG Joshi, CL Emery, G Au, ...
Biosensors and Bioelectronics 130, 73-80, 2019
42019
In Situ, Amplification-free double-stranded mutation detection at 60 copies/ml with thousand-fold wild type in urine
C Kirimli, S Lin, YH Su, WH Shih, WY Shih
Biosensors and Bioelectronics 119, 221-229, 2018
42018
Piezoelectric Plate Sensor (PEPS) for Analysis of Specific KRAS Point Mutations at Low Copy Number in Urine Without DNA Isolation or Amplification
CE Kirimli, WH Shih, WY Shih
Biosensors and Biodetection, 327-348, 2017
22017
piezoelectric plate sensor and uses thereof
WY SHIH, W (US). WU, WH (US). SHIH, MC (US). SOYLU, H (TR). GUO, ...
1*2015
In situ detection of transrenal gene mutations without DNA isolation and amplification using Array Piezoelectric Plate Sensor (PEPS)
CE Kirimli
Drexel University, 2013
12013
Wireless Readout System Modeling for Electrodeless QCM
A Sari, OZ Batur, C Kirmli
2019 16th International Conference on Synthesis, Modeling, Analysis and†…, 2019
2019
Piezoelectric Plate Sensor and Uses Thereof
WY Shih, W Wu, WH Shih, MC Soylu, H Guo, SG Joshi, CE Kirimli, YH Su
US Patent App. 16/216,848, 2019
2019
Activation of Lateral Prefrontal Cortex during a Complex Cognitive Task
CE KIRIMLI, S SUMER, SB ERDOGAN, N TOPALOGLU, A Ata
Biomedical Optics, BSuE62, 2008
2008
The system can't perform the operation now. Try again later.
Articles 1–13