Real-time, in situ DNA hybridization detection with attomolar sensitivity without amplification using (pb (Mg1/3Nb2/3) O3) 0.65–(PbTiO3) 0.35 piezoelectric plate sensors W Wu, CE Kirimli, WH Shih, WY Shih Biosensors and Bioelectronics 43, 391-399, 2013 | 17 | 2013 |
DNA hybridization detection with 100 zM sensitivity using piezoelectric plate sensors with an improved noise-reduction algorithm CE Kirimli, WH Shih, WY Shih Analyst 139 (11), 2754-2763, 2014 | 11 | 2014 |
Specific in situ hepatitis B viral double mutation (HBVDM) detection in urine with 60 copies ml− 1 analytical sensitivity in a background of 250-fold wild type without DNA … CE Kirimli, WH Shih, WY Shih Analyst 140 (5), 1590-1598, 2015 | 9 | 2015 |
Rapid, label-free genetic detection of enteropathogens in stool without genetic isolation or amplification S Han, MC Soylu, CE Kirimli, W Wu, B Sen, SG Joshi, CL Emery, G Au, ... Biosensors and Bioelectronics 130, 73-80, 2019 | 8 | 2019 |
Amplification-free in situ KRAS point mutation detection at 60 copies per mL in urine in a background of 1000-fold wild type CE Kirimli, WH Shih, WY Shih Analyst 141 (4), 1421-1433, 2016 | 8 | 2016 |
Temperature-and flow-enhanced detection specificity of mutated DNA against the wild type with reporter microspheres CE Kirimli, WH Shih, WY Shih Analyst 138 (20), 6117-6126, 2013 | 6 | 2013 |
In Situ, Amplification-free double-stranded mutation detection at 60 copies/ml with thousand-fold wild type in urine C Kirimli, S Lin, YH Su, WH Shih, WY Shih Biosensors and Bioelectronics 119, 221-229, 2018 | 5 | 2018 |
Piezoelectric Plate Sensor (PEPS) for Analysis of Specific KRAS Point Mutations at Low Copy Number in Urine Without DNA Isolation or Amplification CE Kirimli, WH Shih, WY Shih Biosensors and Biodetection, 327-348, 2017 | 2 | 2017 |
piezoelectric plate sensor and uses thereof WY SHIH, W (US). WU, WH (US). SHIH, MC (US). SOYLU, H (TR). GUO, ... | 1* | 2015 |
In situ detection of transrenal gene mutations without DNA isolation and amplification using Array Piezoelectric Plate Sensor (PEPS) CE Kirimli Drexel University, 2013 | 1 | 2013 |
Wireless Readout System Modeling for Electrodeless QCM A Sari, OZ Batur, C Kirmli 2019 16th International Conference on Synthesis, Modeling, Analysis and …, 2019 | | 2019 |
Piezoelectric Plate Sensor and Uses Thereof WY Shih, W Wu, W Shih, MC Soylu, H Guo, SG Joshi, CE Kirimli, Y Su US Patent App. 16/216,848, 2019 | | 2019 |
SMACD 2019-16TH INTERNATIONAL CONFERENCE ON SYNTHESIS, MODELING, ANALYSIS AND SIMULATION METHODS AND APPLICATIONS TO CIRCUIT DESIGN, PROCEEDINGS G Floros, N Evmorfonoulos, G Stamoulis, A Sari, OZ Batur, C Kirmli, ... | | 2019 |
Activation of Lateral Prefrontal Cortex during a Complex Cognitive Task CE KIRIMLI, S SUMER, SB ERDOGAN, N TOPALOGLU, A Ata Biomedical Optics, BSuE62, 2008 | | 2008 |