Fabian Braun
TitleCited byYear
Silicon photomultipliers for improved detection of low light levels in miniature near-infrared spectroscopy instruments
R Zimmermann, F Braun, T Achtnich, O Lambercy, R Gassert, M Wolf
Biomedical optics express 4 (5), 659-666, 2013
372013
A versatile noise performance metric for electrical impedance tomography algorithms
F Braun, M Proença, J Solà, JP Thiran, A Adler
IEEE Transactions on Biomedical Engineering 64 (10), 2321-2330, 2017
172017
Non-invasive monitoring of pulmonary artery pressure from timing information by EIT: experimental evaluation during induced hypoxia
M Proença, F Braun, J Solà, A Adler, M Lemay, JP Thiran, SF Rimoldi
Physiological measurement 37 (6), 713, 2016
142016
Influence of heart motion on cardiac output estimation by means of electrical impedance tomography: a case study
M Proença, F Braun, M Rapin, J Solà, A Adler, B Grychtol, SH Bohm, ...
Physiological measurement 36 (6), 1075, 2015
142015
Imaging photoplethysmography: What are the best locations on the face to estimate heart rate?
S Fallet, V Moser, F Braun, JM Vesin
2016 Computing in Cardiology Conference (CinC), 341-344, 2016
132016
Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
F Braun, M Proença, A Adler, T Riedel, JP Thiran, J Solà
PloS one 13 (1), e0191870, 2018
112018
EIDORS Version 3.9
A Adler, A Boyle, F Braun, MG Crabb, B Grychtol, WRB Lionheart, ...
ELECTRICAL IMPEDANCE TOMOGRAPHY! 21, 63, 2017
112017
Body-monitoring with photonic textiles: a reflective heartbeat sensor based on polymer optical fibres
BM Quandt, F Braun, D Ferrario, RM Rossi, A Scheel-Sailer, M Wolf, ...
Journal of The Royal Society Interface 14 (128), 20170060, 2017
112017
Optimization of novel melt-extruded polymer optical fibers designed for pressure sensor applications
BM Quandt, R Hufenus, B Weisse, F Braun, M Wolf, A Scheel-Sailer, ...
European Polymer Journal 88, 44-55, 2017
112017
Cooperative dry-electrode sensors for multi-lead biopotential and bioimpedance monitoring
M Rapin, M Proença, F Braun, C Meier, J Solà, D Ferrario, ...
Physiological measurement 36 (4), 767, 2015
112015
Aortic blood pressure measured via EIT: investigation of different measurement settings
F Braun, M Proença, M Rapin, M Lemay, A Adler, B Grychtol, J Solà, ...
Physiological measurement 36 (6), 1147, 2015
102015
Continuous non-invasive monitoring of blood pressure in the operating room: a cuffless optical technology at the fingertip
J Solà, M Proença, F Braun, N Pierrel, Y Degiorgis, C Verjus, M Lemay, ...
Current Directions in Biomedical Engineering 2 (1), 267-271, 2016
92016
Limitations and challenges of EIT-based monitoring of stroke volume and pulmonary artery pressure
F Braun, M Proença, M Lemay, M Bertschi, A Adler, JP Thiran, J Solà
Physiological measurement 39 (1), 014003, 2018
72018
Origins of cardiosynchronous signals in EIT
A Adler, M Proença, F Braun, JX Brunner, J Solà
ELECTRICAL IMPEDANCE TOMOGRAPHY! 21, 73, 2017
62017
Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study
M Proença, F Braun, J Solà, JP Thiran, M Lemay
Medical & biological engineering & computing 55 (6), 949-963, 2017
62017
Real-time respiratory rate estimation using imaging photoplethysmography inter-beat intervals
L Mirmohamadsadeghi, S Fallet, V Moser, F Braun, JM Vesin
2016 Computing in Cardiology Conference (CinC), 861-864, 2016
62016
Real-time approaches for heart rate monitoring using imaging photoplethysmography
S Fallet, L Mirmohamadsadeghi, V Moser, F Braun, JM Vesin
2016 Computing in Cardiology Conference (CinC), 345-348, 2016
62016
Systolic Time Intervals Measured by Electrical Impedance Tomography (EIT)
F Braun
Eidgenössische Technische Hochschule Zürich, Computer Vision Laboratory, 2013
62013
Wearable Sensors for Frequency-Multiplexed EIT and Multilead ECG Data Acquisition
M Rapin, F Braun, A Adler, J Wacker, I Frerichs, B Vogt, O Chételat
IEEE Transactions on Biomedical Engineering 66 (3), 810-820, 2018
52018
Imaging photoplethysmography: A real-time signal quality index
S Fallet, Y Schoenenberger, L Martin, F Braun, V Moser, JM Vesin
2017 Computing in Cardiology (CinC), 1-4, 2017
52017
The system can't perform the operation now. Try again later.
Articles 1–20