Follow
Randy W Purves
Randy W Purves
CFIA, University of Saskatchewan, NRC, Ionalytics
Verified email at usask.ca
Title
Cited by
Cited by
Year
Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometer
RW Purves, R Guevremont, S Day, CW Pipich, MS Matyjaszczyk
Review of Scientific Instruments 69 (12), 4094-4105, 1998
3611998
Electrospray ionization high-field asymmetric waveform ion mobility spectrometry− mass spectrometry
RW Purves, R Guevremont
Analytical chemistry 71 (13), 2346-2357, 1999
3391999
Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
R Guevremont, RW Purves
Review of Scientific Instruments 70 (2), 1370-1383, 1999
3271999
The hexanoyl‐CoA precursor for cannabinoid biosynthesis is formed by an acyl‐activating enzyme in Cannabis sativa trichomes
JM Stout, Z Boubakir, SJ Ambrose, RW Purves, JE Page
The Plant Journal 71 (3), 353-365, 2012
2112012
Stable and recyclable Au 25 clusters for the reduction of 4-nitrophenol
A Shivhare, SJ Ambrose, H Zhang, RW Purves, RWJ Scott
Chemical Communications 49 (3), 276-278, 2013
1652013
Application of ESI-FAIMS-MS to the analysis of tryptic peptides
DA Barnett, B Ells, R Guevremont, RW Purves
Journal of the American Society for Mass Spectrometry 13 (11), 1282-1291, 2002
1502002
Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS
R Guevremont, DA Barnett, RW Purves, J Vandermey
Analytical chemistry 72 (19), 4577-4584, 2000
1492000
Analysis of a series of chlorogenic acid isomers using differential ion mobility and tandem mass spectrometry
JL Willems, MM Khamis, WM Saeid, RW Purves, G Katselis, NH Low, ...
Analytica chimica acta 933, 164-174, 2016
1442016
Separation of leucine and isoleucine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry
DA Barnett, B Ells, R Guevremont, RW Purves
Journal of the American Society for Mass Spectrometry 10 (12), 1279-1284, 1999
1421999
Apparatus and method for desolvating and focussing ions for introduction into a mass spectrometer
R Guevremont, RW Purves
US Patent 6,504,149, 2003
1332003
High field asymmetric waveform ion mobility spectrometry-mass spectrometry: an investigation of leucine enkephalin ions produced by electrospray ionization
R Guevremont, RW Purves
Journal of the American Society for Mass Spectrometry 10 (6), 492-501, 1999
1301999
Quantitation of amphetamine, methamphetamine, and their methylenedioxy derivatives in urine by solid-phase microextraction coupled with electrospray ionization− high-field …
MA McCooeye, Z Mester, B Ells, DA Barnett, RW Purves, R Guevremont
Analytical chemistry 74 (13), 3071-3075, 2002
1232002
Detection of nine chlorinated and brominated haloacetic acids at part-per-trillion levels using ESI-FAIMS-MS
B Ells, DA Barnett, RW Purves, R Guevremont
Analytical chemistry 72 (19), 4555-4559, 2000
1232000
Elongated conformers of charge states+ 11 to+ 15 of bovine ubiquitin studied using ESI-FAIMS-MS
RW Purves, DA Barnett, B Ells, R Guevremont
Journal of the American Society for Mass Spectrometry 12 (8), 894-901, 2001
1172001
Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry
DA Barnett, B Ells, R Guevremont, RW Purves, LA Viehland
Journal of the American Society for Mass Spectrometry 11 (12), 1125-1133, 2000
1172000
Calculation of ion mobilities from electrospray ionization high-field asymmetric waveform ion mobility spectrometry mass spectrometry
R Guevremont, DA Barnett, RW Purves, LA Viehland
The Journal of Chemical Physics 114 (23), 10270-10277, 2001
1152001
Determination of nanomolar levels of perchlorate in water by ESI-FAIMS-MS
R Handy, DA Barnett, RW Purves, G Horlick, R Guevremont
Journal of Analytical Atomic Spectrometry 15 (8), 907-911, 2000
1132000
Investigation of bovine ubiquitin conformers separated by high-field asymmetric waveform ion mobility spectrometry: cross section measurements using energy-loss experiments …
RW Purves, DA Barnett, B Ells, R Guevremont
Journal of the American Society for Mass Spectrometry 11 (8), 738-745, 2000
1112000
Separation of protein conformers using electrospray-high field asymmetric waveform ion mobility spectrometry-mass spectrometry
RW Purves, DA Barnett, R Guevremont
International Journal of Mass Spectrometry 197 (1-3), 163-177, 2000
1082000
Eliminating vicine and convicine, the main anti-nutritional factors restricting faba bean usage
H Khazaei, RW Purves, J Hughes, W Link, DM O'Sullivan, AH Schulman, ...
Trends in Food Science & Technology 91, 549-556, 2019
1022019
The system can't perform the operation now. Try again later.
Articles 1–20