Kelly C McPhee
Kelly C McPhee
CancerCare Manitoba
Verified email at ualberta.ca
Title
Cited by
Cited by
Year
Hyperbranched polyglycerols as trimodal imaging agents: design, biocompatibility, and tumor uptake
K Saatchi, P Soema, N Gelder, R Misri, K McPhee, JHE Baker, ...
Bioconjugate chemistry 23 (3), 372-381, 2012
512012
Transverse relaxation and flip angle mapping: evaluation of simultaneous and independent methods using multiple spin echoes
KC McPhee, AH Wilman
Magnetic resonance in medicine 77 (5), 2057-2065, 2017
322017
T2 quantification from only proton density and T2-weighted MRI by modelling actual refocusing angles
KC McPhee, AH Wilman
NeuroImage 118, 642-650, 2015
212015
Bilateral filtering of magnetic resonance phase images
KC McPhee, C Denk, Z AlRekabi, A Rauscher
Magnetic resonance imaging 29 (7), 1023-1029, 2011
152011
Limitations of skipping echoes for exponential T2 fitting
KC McPhee, AH Wilman
Journal of Magnetic Resonance Imaging 48 (5), 1432-1440, 2018
132018
Recovery of accurate T2 from historical 1.5 tesla proton density and T2-weighted images: Application to 7-year T2 changes in multiple sclerosis brain
MN Uddin, KC McPhee, G Blevins, AH Wilman
Magnetic Resonance Imaging 37, 21-26, 2017
62017
Value of Independent Flip Angle Mapping for Transverse Relaxometry with Stimulated Echo Compensation
D Breitkreutz, KC McPhee, W AH
Proc Intl Soc Mag Reson Med, 2466, 2013
32013
Presurgical Visualization of Cerebral Surface Veins with Susceptibility Weighted Imaging
Z Al-Rekabi, K McPhee, K Fitzpatrick, B Bjornson, A Rauscher
Proc Intl Soc Mag Reson Med 17, 44, 2009
32009
T1 and T2 quantification from standard turbo spin echo images
KC McPhee, AH Wilman
Magnetic resonance in medicine 81 (3), 2052-2063, 2019
22019
Multi‐modal magnetic resonance imaging and histology of vascular function in xenografts using macromolecular contrast agent hyperbranched polyglycerol (HPG‐GdF)
JHE Baker, KC McPhee, F Moosvi, K Saatchi, UO Häfeli, AI Minchinton, ...
Contrast media & molecular imaging 11 (1), 77-88, 2016
22016
Delayed Bolus Arrival Time with High Molecular Weight Contrast Agent, an Indicator of Necrosis
KC McPhee, JHE Baker, K Saatchi, UO Hafeli, SA Reinsberg
Proc Intl Soc Mag Reson Med 20, 1528, 2012
12012
Extravasation of a New High Molecular Weight Contrast Agent in Tumour Vasculature, Probed by MRI & Histology
KC McPhee, JHE Baker, K Saatchi, UO Hafeli, SA Reinsberg
Proc Intl Soc Mag Reson Med 19, 1685, 2011
12011
Bloch modelling enables robust T2 mapping using retrospective Proton Density and T2-weighted images from different vendors and sites
G Chhetri, KC McPhee, AH Wilman, ...
NeuroImage, 118116, 2021
2021
Comparison of Vendor Provided Analysis Vs Computational Sequence Modeling for T2 Mapping
K McPhee, A Wilman
MEDICAL PHYSICS 46 (6), E109-E109, 2019
2019
T2 Quantification Using Only T2-weighted and Proton Density Weighted Fast Spin Echo Images
KC McPhee, AH Wilman
Proc Intl Soc Mag Reson Med 22, 3195, 2014
2014
3D Variable Flip Angle Fast-Low-Angle-Shot Experiments in the Presence of B1 Inhomogeneity and Slab-Select Gradient
KC McPhee, SA Reinsberg
Proc Intl Soc Mag Reson Med 20, 2440, 2012
2012
Characterization of tumour vasculature with dynamic contrast enhanced MRI and Gd-hyperbranched polyglycerols
KC McPhee
University of British Columbia, 2012
2012
Quantification of T1 and T2 from Standard MR Images
KC McPhee, AH Wilman
Whole Body Rapid T2 Quantification using Dual Echo Fast Spin Echo
KC McPhee, A De, AH Wilman
The system can't perform the operation now. Try again later.
Articles 1–19