Follow
Steven C Koenig
Steven C Koenig
Professor of Bioengineering and Surgery, University of Louisville
Verified email at louisville.edu
Title
Cited by
Cited by
Year
H2S Protects Against Pressure Overload–Induced Heart Failure via Upregulation of Endothelial Nitric Oxide Synthase
K Kondo, S Bhushan, AL King, SD Prabhu, T Hamid, S Koenig, ...
Circulation 127 (10), 1116-1127, 2013
3852013
Predictors of death and transplant in patients with a mechanical circulatory support device: a multi-institutional study
WL Holman, RL Kormos, DC Naftel, MA Miller, FD Pagani, E Blume, ...
The Journal of Heart and Lung Transplantation 28 (1), 44-50, 2009
2292009
Characterization of an adult mock circulation for testing cardiac support devices
GM Pantalos, SC Koenig, KJ Gillars, GA Giridharan, DL Ewert
ASAIO journal 50 (1), 37-46, 2004
2122004
Vascular pulsatility in patients with a pulsatile-or continuous-flow ventricular assist device
AR Travis, GA Giridharan, GM Pantalos, RD Dowling, SD Prabhu, ...
The Journal of thoracic and cardiovascular surgery 133 (2), 517-524, 2007
1832007
Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG
SF Jaber, SC Koenig, B BhaskerRao, DJ VanHimbergen, PB Cerrito, ...
The Annals of thoracic surgery 66 (3), 1087-1092, 1998
1371998
Evidence for Improved Cerebral Function After Minimally lnvasive Bypass Surgery
B BhaskerRao, D VanHimbergen, HL Edmonds Jr, S Jaber, AT Ali, ...
Journal of cardiac surgery 13 (1), 27-31, 1998
1241998
Paradoxical effect of nonphysiological shear stress on platelets and v on W illebrand factor
Z Chen, NK Mondal, J Ding, SC Koenig, MS Slaughter, ZJ Wu
Artificial organs 40 (7), 659-668, 2016
992016
Rotary pump speed modulation for generating pulsatile flow and phasic left ventricular volume unloading in a bovine model of chronic ischemic heart failure
KG Soucy, GA Giridharan, Y Choi, MA Sobieski, G Monreal, A Cheng, ...
The Journal of Heart and Lung Transplantation 34 (1), 122-131, 2015
952015
Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist
GA Giridharan, SC Koenig, J Kennington, MA Sobieski, J Chen, ...
The Journal of thoracic and cardiovascular surgery 145 (1), 249-257, 2013
952013
Defining pulsatility during continuous-flow ventricular assist device support
KG Soucy, SC Koenig, GA Giridharan, MA Sobieski, MS Slaughter
The Journal of Heart and Lung Transplantation 32 (6), 581-587, 2013
912013
Activation and shedding of platelet glycoprotein IIb/IIIa under non-physiological shear stress
Z Chen, NK Mondal, J Ding, SC Koenig, MS Slaughter, BP Griffith, ZJ Wu
Molecular and cellular biochemistry 409, 93-101, 2015
892015
Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle
CR Bartoli, GA Giridharan, KN Litwak, M Sobieski, SD Prabhu, ...
Asaio Journal 56 (5), 410-416, 2010
892010
Flow modulation algorithms for continuous flow left ventricular assist devices to increase vascular pulsatility: a computer simulation study
M Ising, S Warren, MA Sobieski, MS Slaughter, SC Koenig, GA Giridharan
Cardiovascular engineering and technology 2, 90-100, 2011
792011
Hemodynamic and pressure–volume responses to continuous and pulsatile ventricular assist in an adult mock circulation
SC Koenig, GM Pantalos, KJ Gillars, DL Ewert, KN Litwak, SW Etoch
ASAIO journal 50 (1), 15-24, 2004
792004
Results after partial left ventriculectomy versus heart transplantation for idiopathic cardiomyopathy
SW Etoch, SC Koenig, MA Laureano, P Cerrito, LA Gray, RD Dowling
The Journal of Thoracic and Cardiovascular Surgery 117 (5), 952-959, 1999
741999
Miniaturization of mechanical circulatory support systems
GA Giridharan, TJ Lee, M Ising, MA Sobieski, SC Koenig, LA Gray, ...
Artificial organs 36 (8), 731-739, 2012
722012
Intraoperative evaluation of the HeartMate II flow estimator
MS Slaughter, CR Bartoli, MA Sobieski, GM Pantalos, GA Giridharan, ...
The Journal of heart and lung transplantation 28 (1), 39-43, 2009
712009
Flow features and device‐induced blood trauma in CF‐VADs under a pulsatile blood flow condition: a CFD comparative study
Z Chen, SK Jena, GA Giridharan, SC Koenig, MS Slaughter, BP Griffith, ...
International journal for numerical methods in biomedical engineering 34 (2 …, 2018
702018
Rotary pumps and diminished pulsatility: do we need a pulse?
KG Soucy, SC Koenig, GA Giridharan, MA Sobieski, MS Slaughter
aSaiO Journal 59 (4), 355-366, 2013
672013
High shear induces platelet dysfunction leading to enhanced thrombotic propensity and diminished hemostatic capacity
Z Chen, NK Mondal, S Zheng, SC Koenig, MS Slaughter, BP Griffith, ...
Platelets 30 (1), 112-119, 2019
652019
The system can't perform the operation now. Try again later.