Philippe Büchler
Philippe Büchler
Verified email at artorg.unibe.ch
TitleCited byYear
Risks of loosening of a prosthetic glenoid implanted in retroversion
A Farron, A Terrier, P Büchler
Journal of shoulder and elbow surgery 15 (4), 521-526, 2006
2312006
A finite element model of the shoulder: application to the comparison of normal and osteoarthritic joints
P Büchler, NA Ramaniraka, LR Rakotomanana, JP Iannotti, A Farron
Clinical Biomechanics 17 (9-10), 630-639, 2002
1612002
The virtual skeleton database: an open access repository for biomedical research and collaboration
M Kistler, S Bonaretti, M Pfahrer, R Niklaus, P Büchler
Journal of medical Internet research 15 (11), e245, 2013
1262013
Biomechanical model of human cornea based on stromal microstructure
H Studer, X Larrea, H Riedwyl, P Büchler
Journal of biomechanics 43 (5), 836-842, 2010
832010
Influence of glenohumeral conformity on glenoid stresses after total shoulder arthroplasty
A Terrier, P Büchler, A Farron
Journal of shoulder and elbow surgery 15 (4), 515-520, 2006
782006
Benefits of an anatomical reconstruction of the humeral head during shoulder arthroplasty: a finite element analysis
P Büchler, A Farron
Clinical biomechanics 19 (1), 16-23, 2004
782004
Bone–cement interface of the glenoid component: stress analysis for varying cement thickness
A Terrier, P Büchler, A Farron
Clinical biomechanics 20 (7), 710-717, 2005
732005
Optimisation of orthopaedic implant design using statistical shape space analysis based on level sets
N Kozic, S Weber, P Büchler, C Lutz, N Reimers, MÁG Ballester, M Reyes
Medical image analysis 14 (3), 265-275, 2010
622010
Statismo-A framework for PCA based statistical models
M Lüthi, R Blanc, T Albrecht, T Gass, O Goksel, P Büchler, M Kistler, ...
The Insight Journal 2012, 1-18, 2012
572012
Statistical finite element model for bone shape and biomechanical properties
LB Querol, P Büchler, D Rueckert, LP Nolte, MÁG Ballester
International Conference on Medical Image Computing and Computer-Assisted …, 2006
442006
Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials.
T Bardyn, P Gédet, W Hallermann, P Büchler
International journal of oral & maxillofacial implants 24 (6), 2009
412009
Stress free configuration of the human eye
A Elsheikh, C Whitford, R Hamarashid, W Kassem, A Joda, P Büchler
Medical engineering & physics 35 (2), 211-216, 2013
392013
Multiscale modeling for image analysis of brain tumor studies
S Bauer, C May, D Dionysiou, G Stamatakos, P Buchler, M Reyes
IEEE transactions on biomedical engineering 59 (1), 25-29, 2011
392011
Oxygen and glucose distribution after intracorneal lens implantation
X Larrea, C De Courten, V Feingold, J Burger, P Buechler
Optometry and vision science 84 (12), 1074-1081, 2007
362007
Artificial muscle devices: innovations and prospects for fecal incontinence treatment
E Fattorini, T Brusa, C Gingert, SE Hieber, V Leung, B Osmani, ...
Annals of biomedical engineering 44 (5), 1355-1369, 2016
352016
Patient-specific finite-element simulation of the human cornea: a clinical validation study on cataract surgery
HP Studer, H Riedwyl, CA Amstutz, JVM Hanson, P Büchler
Journal of biomechanics 46 (4), 751-758, 2013
342013
Coupling biomechanics to a cellular level model: an approach to patient-specific image driven multi-scale and multi-physics tumor simulation
CP May, E Kolokotroni, GS Stamatakos, P Büchler
Progress in biophysics and molecular biology 107 (1), 193-199, 2011
332011
Objective compliance of adolescent girls with idiopathic scoliosis in a dynamic SpineCor brace
CC Hasler, S Wietlisbach, P Büchler
Journal of children's orthopaedics 4 (3), 211-218, 2010
332010
Atlas-based segmentation of brain tumor images using a Markov random field-based tumor growth model and non-rigid registration
S Bauer, C Seiler, T Bardyn, P Buechler, M Reyes
2010 Annual International Conference of the IEEE Engineering in Medicine and …, 2010
312010
Biphasic constitutive laws for biological interface evolution
P Büchler, DP Pioletti, LR Rakotomanana
Biomechanics and modeling in mechanobiology 1 (4), 239-249, 2003
312003
The system can't perform the operation now. Try again later.
Articles 1–20