Follow
Nick Zwart
Nick Zwart
Assistant Research Professor, Barrow Neurological Institute
Verified email at dignityhealth.org
Title
Cited by
Cited by
Year
A new design and rationale for 3D orthogonally oversampled k‐space trajectories
JG Pipe, NR Zwart, EA Aboussouan, RK Robison, A Devaraj, KO Johnson
Magnetic resonance in medicine 66 (5), 1303-1311, 2011
1232011
Efficient sample density estimation by combining gridding and an optimized kernel
NR Zwart, KO Johnson, JG Pipe
Magnetic resonance in medicine 67 (3), 701-710, 2012
1152012
Turboprop: improved PROPELLER imaging
JG Pipe, N Zwart
Magnetic Resonance in Medicine: An Official Journal of the International …, 2006
1142006
ISMRM Raw data format: A proposed standard for MRI raw datasets
SJ Inati, JD Naegele, NR Zwart, V Roopchansingh, MJ Lizak, DC Hansen, ...
Magnetic resonance in medicine 77 (1), 411-421, 2017
1032017
Spiral trajectory design: a flexible numerical algorithm and base analytical equations
JG Pipe, NR Zwart
Magnetic Resonance in Medicine 71 (1), 278-285, 2014
782014
Graphical programming interface: a development environment for MRI methods
NR Zwart, JG Pipe
Magnetic resonance in medicine 74 (5), 1449-1460, 2015
732015
Revised motion estimation algorithm for PROPELLER MRI
JG Pipe, WN Gibbs, Z Li, JP Karis, M Schar, NR Zwart
Magnetic resonance in medicine 72 (2), 430-437, 2014
542014
Joint water–fat separation and deblurring for spiral imaging
D Wang, NR Zwart, JG Pipe
Magnetic Resonance in Medicine 79 (6), 3218-3228, 2018
492018
Multidirectional high‐moment encoding in phase contrast MRI
NR Zwart, JG Pipe
Magnetic resonance in medicine 69 (6), 1553-1563, 2013
362013
Arterial spin labeled perfusion imaging using three‐dimensional turbo spin echo with a distributed spiral‐in/out trajectory
Z Li, M Schär, D Wang, NR Zwart, AJ Madhuranthakam, JP Karis, JG Pipe
Magnetic resonance in medicine 75 (1), 266-273, 2016
312016
Analytical three‐point Dixon method: With applications for spiral water–fat imaging
D Wang, NR Zwart, Z Li, M Schär, JG Pipe
Magnetic resonance in medicine 75 (2), 627-638, 2016
292016
Dixon water‐fat separation in PROPELLER MRI acquired with two interleaved echoes
M Schär, H Eggers, NR Zwart, Y Chang, A Bakhru, JG Pipe
Magnetic resonance in medicine 75 (2), 718-728, 2016
272016
Sliding‐slab three‐dimensional TSE imaging with a spiral‐in/out readout
Z Li, D Wang, RK Robison, NR Zwart, M Schär, JP Karis, JG Pipe
Magnetic resonance in medicine 75 (2), 729-738, 2016
272016
The effects of SENSE on PROPELLER imaging
Y Chang, JG Pipe, JP Karis, WN Gibbs, NR Zwart, M Schär
Magnetic resonance in medicine 74 (6), 1598-1608, 2015
272015
Multi-frequency interpolation in spiral magnetic resonance fingerprinting for correction of off-resonance blurring
J Ostenson, RK Robison, NR Zwart, EB Welch
Magnetic resonance imaging 41, 63-72, 2017
242017
Fast, variable system delay correction for spiral MRI
PS Bhavsar, NR Zwart, JG Pipe
Magnetic Resonance in Medicine 71 (2), 773-782, 2014
182014
Spiral T1 spin-echo for routine postcontrast brain MRI exams: a multicenter multireader clinical evaluation
MB Ooi, Z Li, RK Robison, D Wang, AG Anderson, NR Zwart, A Bakhru, ...
American Journal of Neuroradiology 41 (2), 238-245, 2020
172020
Freeing MRI from its Faraday cage with Interference Rejection
H Dyvorne, T Rearick, M Poole, C Lazarus, P Weiss, L Sacolick, J Jordan, ...
Proceedings of the 29th Annual Meeting of ISMRM 749, 2021
82021
Spiral CG deblurring and fat-water separation using a multi-peak fat model
NR Zwart, D Wang, JG Pipe
Proceedings of the Joint Annual Meeting of ISMRM-ESMRMB, Milan, Italy, 2014
72014
Use environments and clinical feasibility of portable point-of-care bedside brain MRI
EB Welch, S By, G Chen, H Dyvorne, C Hugon, C McNulty
Proceedings of the ISMRM. Virtual, 2020
32020
The system can't perform the operation now. Try again later.
Articles 1–20