Follow
Iacovos S Kyprianou
Iacovos S Kyprianou
Senior Science Health Advisor, Center for Devices and Radiological Health, US FDA
Verified email at fda.hhs.gov
Title
Cited by
Cited by
Year
Monte Carlo study of the effects of system geometry and antiscatter grids on cone‐beam CT scatter distributions
A Sisniega, W Zbijewski, A Badal, IS Kyprianou, JW Stayman, JJ Vaquero, ...
Medical physics 40 (5), 051915, 2013
1392013
Comprehensive methodology for the evaluation of radiation dose in x-ray computed tomography
RL Dixon, JA Anderson, DM Bakalyar
1152010
Generalizing the MTF and DQE to include x‐ray scatter and focal spot unsharpness: Application to a new microangiographic system
IS Kyprianou, S Rudin, DR Bednarek, KR Hoffmann
Medical physics 32 (2), 613-626, 2005
1072005
Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195
I Sechopoulos, ESM Ali, A Badal, A Badano, JM Boone, IS Kyprianou, ...
Medical physics 42 (10), 5679-5691, 2015
962015
penMesh—Monte Carlo Radiation Transport Simulation in a Triangle Mesh Geometry
A Badal, I Kyprianou, DP Banh, A Badano, J Sempau
IEEE transactions on medical imaging 28 (12), 1894-1901, 2009
642009
Measurement of flow modification in phantom aneurysm model: Comparison of coils and a longitudinally and axially asymmetric stent—Initial findings
S Rudin, Z Wang, I Kyprianou, KR Hoffmann, Y Wu, H Meng, ...
Radiology 231 (1), 272-276, 2004
612004
Anisotropic imaging performance in breast tomosynthesis
A Badano, IS Kyprianou, RJ Jennings, J Sempau
Medical physics 34 (11), 4076-4091, 2007
532007
Study of the generalized MTF and DQE for a new microangiographic system
IS Kyprianou, S Rudin, DR Bednarek, KR Hoffmann
Medical Imaging 2004: Physics of Medical Imaging 5368, 349-360, 2004
502004
Micro‐angiography for neuro‐vascular imaging. I. Experimental evaluation and feasibility
A Ganguly, S Rudin, DR Bednarek, KR Hoffmann, IS Kyprianou
Medical physics 30 (11), 3018-3028, 2003
472003
Anisotropic imaging performance in indirect x‐ray imaging detectors
A Badano, IS Kyprianou, J Sempau
Medical physics 33 (8), 2698-2713, 2006
462006
Micro-angiographic detector with fluoroscopic capability
S Rudin, Y Wu, IS Kyprianou, CN Ionita, Z Wang, A Ganguly, ...
Medical Imaging 2002: Physics of Medical Imaging 4682, 344-354, 2002
412002
Signal detection and location‐dependent noise in cone‐beam computed tomography using the spatial definition of the Hotelling SNR
CC Brunner, SF Abboud, C Hoeschen, IS Kyprianou
Medical physics 39 (6Part1), 3214-3228, 2012
282012
Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system
GK Yadava, IS Kyprianou, S Rudin, DR Bednarek, KR Hoffmann
Medical Imaging 2005: Physics of Medical Imaging 5745, 419-429, 2005
262005
Material-specific transfer function model and SNR in CT
CC Brunner, IS Kyprianou
Physics in Medicine & Biology 58 (20), 7447, 2013
252013
Singular value description of a digital radiographic detector: Theory and measurements
IS Kyprianou, A Badano, BD Gallas, KJ Myers
Medical physics 35 (10), 4744-4756, 2008
232008
Computational high-resolution heart phantoms for medical imaging and dosimetry simulations
S Gu, R Gupta, I Kyprianou
Physics in Medicine & Biology 56 (18), 5845, 2011
212011
Monte Carlo simulation of a realistic anatomical phantom described by triangle meshes: application to prostate brachytherapy imaging
A Badal, I Kyprianou, A Badano, J Sempau
Radiotherapy and Oncology 86 (1), 99-103, 2008
202008
Efficiency of the human observer compared to an ideal observer based on a generalized NEQ which incorporates scatter and geometric unsharpness: evaluation with a 2AFC experiment
IS Kyprianou, A Ganguly, S Rudin, DR Bednarek, BD Gallas, KJ Myers
Medical Imaging 2005: Image Perception, Observer Performance, and Technology …, 2005
192005
A practical method for measuring the H matrix of digital x-ray and cone beam CT imaging systems
IS Kyprianou, A Badano, BD Gallas, S Park, KJ Myers
Medical Imaging 2006: Physics of Medical Imaging 6142, 652-663, 2006
172006
Effect of oblique x-ray incidence in flat-panel computed tomography of the breast
A Badano, IS Kyprianou, M Freed, RJ Jennings, J Sempau
IEEE transactions on medical imaging 28 (5), 696-702, 2008
162008
The system can't perform the operation now. Try again later.
Articles 1–20