Modeling of radio‐frequency induced currents on lead wires during MR imaging using a modified transmission line method
V Acikel, E Atalar
Medical Physics 38 (12), 6623-6632, 2011
452011
A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI
B Silemek, V Acikel, C Oto, A Alipour, ZG Aykut, O Algin, E Atalar
Magnetic resonance in medicine 79 (5), 2824-2832, 2018
142018
Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging
V Acikel, A Uslubas, E Atalar
Medical physics 42 (7), 3922-3931, 2015
142015
RF induced heating of pacemaker/ICD lead-tips during MRI Scans at 1.5 T and 3T: evaluation in cadavers
DBE Volkan Acikel, Patrick Magrath, Scott E Parker, Peng Hu, Holden H Wu, J ...
Journal of Cardiovascular Magnetic Resonance 18 (1), O121, 2016
82016
A novel MRI based electrical properties measurement technique
V Acikel, O Ulutan, AC Ozen, B Akin, Y Eryaman, E Atalar
Proc. Intl. Soc. Mag. Reson. Med 21, 2013
42013
Intravascular magnetic resonance imaging (MRI)
V Acikel, E Atalar
Biomedical Imaging, 186-213, 2014
32014
Localizing the excitation to reduce scan time using nonlinear gradient fields
E Kopanoğlu, U Yılmaz, B Akın, V Açıkel, E Atalar
Proceedings of the International Society for Magnetic Resonance in Medicine, 2012
32012
Wireless control of induced radiofrequency currents in active implantable medical devices during MRI
V Acikel, B Silemek, E Atalar
Magnetic Resonance in Medicine 83 (6), 2370-2381, 2020
22020
Analysis of current induction on thin conductors inside the body during MRI scan
V Açıkel
bilkent university, 2014
22014
Decreasing SAR of a multi-dimensional central brightening inhomogeneity correction pulse using nonlinear gradient fields and VERSE
E Kopanoğlu, Y Gökhalk, U Yılmaz, V Açıkel, E Atalar
20th ISMRM Annual Meeting and Exhibition, ISMRM 2012, 3470, 2012
22012
Modeling of RF induced implant lead current for MRI
V Acikel, E Atalar
17th Annu. Meet. ISMRM, Honolulu, HI, 2009
22009
Effect of linear phase electric field variation on implant lead heating
Y Eryaman, V Acikel, E Abaci Turk, NV Viskusenko, E Atalar
Proceedings of the 18th Annual Meeting of ISMRM, Stocknolm, Sweden: Mira …, 2010
12010
A Novel Method for MRI Safe Lead Design
V Acikel, E Atalar
Proc. Intl. Soc. Mag. Reson. Med 22, 4889, 2014
2014
A Novel MRI Based Electrical Properties Measurement Technique
YEEA V. Acikel, O. Ulutan, A.C. Ozen, B.Akin
ISMRM 21st Annual Meeting, 2013
2013
Effect of implantable pulse generator (IPG) cases on implant tip heating
V Açıkel, A Uslubaş, E Atalar
2012
Effect of Implantable Pulse Generator (IPG) Cases on Implant Tip Heating
EA V. Acikel, A. Uslubas
ESMRMB (European Society for Magnetic Resonance in Medicine and Biology …, 2012
2012
Prediction of Implant Tip Heating Using Modi ed Transmission Line Method (MoTLiM) under MRI
IDMEA V. Acikel, B. Akin
ISMRM - 2010 Annual Meeting Proceedings, 2010
2010
Modeling of radio frequency induced currents on lead wires during MR imaging using a modified transmission line method (MoTLiM)
V Açıkel
bilkent university, 2010
2010
Modified Transmission Line Model for Calculating Induced Current on Coated Implant Wires
VAE Atalar
26th Annual Scientific Meeting of the European Society for Magnetic …, 2009
2009
Modeling of RF Induced Implant Lead Current for MRI
VAE Atalar
ISMRM 17th Annual Meeting and Exhibition, 2009
2009