Paracrine engineering of human cardiac stem cells with insulin‐like growth factor 1 enhances myocardial repair R Jackson, EL Tilokee, N Latham, S Mount, G Rafatian, J Strydhorst, B Ye, ... Journal of the American Heart Association 4 (9), e002104, 2015 | 70 | 2015 |
Evaluation of a thermoplastic immobilization system for breast and chest wall radiation therapy JH Strydhorst, JM Caudrelier, BG Clark, LA Montgomery, G Fox, ... Medical Dosimetry 36 (1), 81-84, 2011 | 25 | 2011 |
A gate evaluation of the sources of error in quantitative90Y PET J Strydhorst, T Carlier, A Dieudonné, M Conti, I Buvat Medical physics 43 (10), 5320-5329, 2016 | 23 | 2016 |
Redesign of the GATE PET coincidence sorter J Strydhorst, I Buvat Physics in Medicine & Biology 61 (18), N522, 2016 | 19 | 2016 |
Reproducibility of serial left ventricle perfusion, volume, and ejection fraction measurements using multiplexed multipinhole SPECT in healthy rats and rats after myocardial … JH Strydhorst, FH Leenen, TD Ruddy, RG Wells Journal of Nuclear Medicine 52 (8), 1285-1292, 2011 | 11 | 2011 |
A modified TEW approach to scatter correction for In‐111 and Tc‐99m dual‐isotope small‐animal SPECT P Prior, R Timmins, J Petryk, J Strydhorst, Y Duan, L Wei, R Glenn Wells Medical Physics 43 (10), 5503-5513, 2016 | 8 | 2016 |
Effects of CT‐based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake JH Strydhorst, TD Ruddy, RG Wells Medical Physics 42 (4), 1818-1824, 2015 | 5 | 2015 |
Quantitative measurement of in vivo tracer concentration in rats with multiplexed multi-pinhole SPECT JH Strydhorst, RG Wells IEEE Transactions on Nuclear Science 61 (3), 1136-1142, 2014 | 4 | 2014 |
Phantom validation of 123-I-mIBG imaging with a dedicated solid state SPECT camera J Strydhorst, RG Wells, T Ruddy Journal of Nuclear Medicine 55 (supplement 1), 1689-1689, 2014 | 2 | 2014 |
Quantitative Multiplexed Multi-pinhole Small-Animal SPECT J Strydhorst Carleton University, 2013 | 2 | 2013 |
Attenuation correction of multiplexed multi-pinhole microSPECT reconstruction J Strydhorst, RG Wells IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2841-2843, 2010 | 2 | 2010 |
SU‐GG‐T‐267: Evaluation of the Accuracy of TomoTherapy Dose Calculations for Shallow‐Depth PTVs J Strydhorst, B Clark, M MacPherson Medical Physics 35 (6Part13), 2786-2786, 2008 | 1 | 2008 |
Improved dose-volume histograms for Y90-PET based dosimetry with partial volume effect and noise compensations by means of region sub-segmentation M Sanchez-Garcia, J Strydhorst, H Levillain, I Gardin, P Buyssens, ... EANM'16, 2016 | | 2016 |
Partial volume effect and noise compensation for improved Dose Volume Histogram in 90Y-SIRT PET based dosimetry M Sanchez-Garcia, J Strydhorst, I Buvat, T Carlier, R Lebtahi, ... Journal of Nuclear Medicine 57 (supplement 2), 1013-1013, 2016 | | 2016 |
Partial volume effect and noise compensation of dose-volume histograms for Y90-PET based dosimetry by means of region sub-segmentation M Sanchez, J Strydhorst, H Levillain, I Gardin, P Buyssens, T Carlier, ... MICCAI Annual Meeting, 2016 | | 2016 |
Improved dose-volume histograms for Y90-PET based dosimetry with partial volume effect and noise compensations by means of region sub-segmentation M Sanchez, J Strydhorst, H Levillain, I Gardin, P Buyssens, T Carlier, ... Annual Congress of the European Association of Nuclear Medicine, 2016 | | 2016 |
Partial volume effect and nois compensation of dose-volume histograms for Y90-PET based dosimetry by means of region sub-segmentation. MS Garcia, J Strydhorst, H Levillain, I Gardin, P Buyssens, T Carlier, ... Medical Imaging Conference, 2016 | | 2016 |
SPECT Instrumentation JH Strydhorst, RA Davies, RG Wells Handbook of Nuclear Cardiology: Cardiac SPECT and Cardiac PET, 103-113, 2012 | | 2012 |
SU‐C‐211‐07: Quantitative Reconstruction of Multiplexed Multi‐Pinhole SPECT with Scatter and Attenuation Correction J Strydhorst, RG Wells Medical Physics 38 (6Part2), 3377-3377, 2011 | | 2011 |
Poster — Thur Eve — 69: Attenuation Correction for 99mTc‐Tetrofosmin Micro SPECT/CT Cardiac Measurements in Rats J Strydhorst, J Lockwood, RG Wells Medical Physics 37 (7Part3), 3900-3900, 2010 | | 2010 |