Follow
Ryan C N Studinski
Ryan C N Studinski
Assistant Professor, University of Ottawa
Verified email at hhsc.ca
Title
Cited by
Cited by
Year
Methodology for examining polarized light interactions with tissues and tissue-like media in the exact backscattering direction
RCN Studinski, IA Vitkin
Journal of biomedical optics 5 (3), 330-337, 2000
682000
Polarization preservation in diffusive scattering from in vivo turbid biological media: effects of tissue optical absorption in the exact backscattering direction
IA Vitkin, RCN Studinski
Optics communications 190 (1-6), 37-43, 2001
572001
MOSFET detectors in quality assurance of tomotherapy treatments
A Cherpak, RCN Studinski, JE Cygler
Radiotherapy and Oncology 86 (2), 242-250, 2008
422008
Estimation of a method detection limit for an in vivo XRF arsenic detection system
RCN Studinski, FE McNeill, DR Chettle, JM O'Meara
Physics in Medicine & Biology 50 (3), 521, 2005
352005
Current practice in total-body irradiation: results of a Canada-wide survey
RCN Studinski, DJ Fraser, RS Samant, MS MacPherson
Current oncology 24 (3), 181-186, 2017
292017
XRF analysis of arsenic‐doped skin phantoms
RCN Studinski, FE McNeill, DR Chettle, JM O'Meara
X‐Ray Spectrometry: An International Journal 33 (4), 285-288, 2004
202004
A method detection limit for potential in vivo arsenic measurements with a 50 W x-ray tube
RCN Studinski, FE McNeill, JM O'Meara, DR Chettle
Physics in Medicine & Biology 51 (21), N381, 2006
162006
The feasibility of in vivo measurement of arsenic and silver by x‐ray fluorescence
R Studinski, J O'Meara, F McNeill
X‐Ray Spectrometry: An International Journal 37 (1), 51-57, 2008
82008
Streamlining regulatory activities within radiation therapy departments using QATrack+
C Angers, R Bottema, L Buckley, R Studinski, D Petzold, F Abbassian, ...
Health Physics 117 (3), 306-312, 2019
52019
SU‐E‐T‐103: Development and Implementation of Web Based Quality Control Software
R Studinski, R Taylor, C Angers, D La Russa, B Clark
Medical Physics 41 (6Part12), 246-246, 2014
22014
Sci‐Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques‐10: Results from Canada Wide Survey on Total Body Irradiation Practice
R Studinski, D Fraser, R Samant, M MacPherson
Medical Physics 43 (8Part3), 4957-4958, 2016
12016
Development of an in vivo method of measuring arsenic with radiation
RCN Studinski
Ph. D. Thesis, 2005
12005
The Canadian experience in commissioning a Halcyon-Linac in a Pinnacle-MOSAIQ based centre
R Vlad, O Ostapiak, R Studinski, K Diamond, M Shim, G Chan, R Hunter
MEDICAL PHYSICS 49 (8), 5692-5692, 2022
2022
A comparison of portal dosimetry for the Varian Halcyon 2.0 and multiple detector systems
K Van Delinder, M Shim, R Studinski, R Vlad
MEDICAL PHYSICS 49 (8), 5691-5691, 2022
2022
Challenges in Organ at Risk Shielding for Arc Total Body Irradiation
R Studinski, D Fraser
MEDICAL PHYSICS 45 (6), E320-E320, 2018
2018
Sci‐Fri AM: Quality, Safety, and Professional Issues 05: QC Program Management and the Benefits of QATrack+
CP Angers, R Bottema, L Buckley, R Studinski
Medical Physics 43 (8Part3), 4953-4954, 2016
2016
Evaluation of a Penile Clamp to Improve Bladder Filling in Patients Undergoing Radiation Therapy for Prostate Cancer
S Malone, G Wright, M Lacelle, L Buckley, R Studinski, A Haridass, ...
International Journal of Radiation Oncology, Biology, Physics 93 (3), E210-E211, 2015
2015
Poster—Thur Eve—72: Conversion of helical tomotherapy plans into clinically favourable step‐and‐shoot IMRT plans deliverable on ac‐arm linac
RCN Studinski, A Alexander, D La Russa
Medical Physics 39 (7Part4), 4638-4638, 2012
2012
Poster—Thur Eve—19: Risk assessment of clinical radiation processes using failure modes and effect analysis
C Angers, R Studinski, D La Russa, J Bahm, J Renaud, BG Clark
Medical Physics 39 (7Part3), 4628-4628, 2012
2012
SU‐E‐T‐404: The Effect of Field/target Size on Quality Assurance of TomoTherapy IMRT Treatments When Using a Diode Array for Absolute and Relative Dose Measurements
C Foottit, D La Russa, R Studinski
Medical Physics 38 (6Part16), 3581-3581, 2011
2011
The system can't perform the operation now. Try again later.
Articles 1–20