Follow
Ravi Chityala
Title
Cited by
Cited by
Year
Self‐calibration of a cone‐beam micro‐CT system
V Patel, RN Chityala, KR Hoffmann, CN Ionita, DR Bednarek, S Rudin
Medical physics 36 (1), 48-58, 2009
1052009
Image processing and acquisition using Python
R Chityala, S Pudipeddi
Chapman and Hall/CRC, 2020
912020
Region of interest (ROI) computed tomography
RN Chityala, KR Hoffmann, DR Bednarek, S Rudin
Medical imaging 2004: Physics of medical imaging 5368, 534-541, 2004
842004
Cone-beam micro-CT system based on LabVIEW software
CN Ionita, KR Hoffmann, DR Bednarek, R Chityala, S Rudin
Journal of digital imaging 21, 296-305, 2008
612008
Region of interest (ROI) computed tomography (CT): comparison with full field of view (FFOV) and truncated CT for a human head phantom
R Chityala, KR Hoffmann, S Rudin, DR Bednarek
Medical Imaging 2005: Physics of Medical Imaging 5745, 583-590, 2005
522005
Artifact reduction in truncated CT using sinogram completion
R Chityala, KR Hoffmann, S Rudin, DR Bednarek
Medical Imaging 2005: Image Processing 5747, 2110-2117, 2005
432005
Handbook of physics in medicine and biology
R Splinter
CRC Press, 2010
382010
New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy
S Rudin, AT Kuhls, GK Yadava, GC Josan, Y Wu, RN Chityala, ...
Medical Imaging 2006: Physics of Medical Imaging 6142, 624-634, 2006
302006
Multi-institutional feasibility study of a fast patient localization method in total marrow irradiation with helical tomotherapy: A global health initiative by the …
Y Takahashi, S Vagge, S Agostinelli, E Han, L Matulewicz, K Schubert, ...
International Journal of Radiation Oncology* Biology* Physics 91 (1), 30-38, 2015
162015
White matter measures correlate with essential tremor severity—A pilot diffusion tensor imaging study
I Nestrasil, A Svatkova, KD Rudser, R Chityala, A Wakumoto, BA Mueller, ...
Brain and behavior 8 (8), e01039, 2018
142018
Segmentation and visualization of a large, high-resolution micro-CT data of mice
R Chityala, S Pudipeddi, L Arensten, S Hui
Journal of digital imaging 26, 302-308, 2013
122013
Cone-beam ct of vessel phantoms: Comparison of image intensifier and high-resolution micro-angiographic systems
C Ionita
Med Phys 30, 1423, 2003
72003
Micro-cone-beam ct for determination of stent coverage of aneurysm orifice
R Chityala
Med Phys 30, 1423, 2003
72003
Region of interest (ROI) cone-beam CT using dual resolution, dual detector image acquisition: Evaluation of off centered ROIs
RN Chityala, V Patel, KR Hoffmann, S Rudin, DR Bednarek
Proc RSNA 923, 2006
62006
System and method for determining the best size of products for online and offline purchase
R Chityala, N Labello
US Patent App. 13/541,934, 2013
52013
Region of interest cone beam computed tomography (ROI-CBCT)
RN Chityala
State University of New York at Buffalo, 2007
52007
SU‐FF‐I‐06: A Portable Test Platform for Image Acquisition and Calibration for Cone Beam Computed Tomography (CBCT) and Region of Interest CBCT (ROI‐CBCT) On a Commercial X‐Ray …
H Rangwala, R Chityala, S Rudin, K Hoffmann
Medical Physics 33 (6Part3), 1997-1998, 2006
52006
MO‐D‐I‐611‐04: Region‐Of‐Interest (ROI) Computed Tomography: Combining Dual Resolution XRII Images
R Chityala, K Hoffmann, S Rudin, D Bednarek
Medical Physics 32 (6Part14), 2056-2056, 2005
52005
High-resolution region-of-interest (ROI) cone-beam CT
RN Chityala, KR Hoffmann, S Rudin, DR Bednarek
Proc RSNA 392, 2005
52005
High-resolution vascular radiological imaging
S Rudin, D Bednarek, R Chityala, P Dinu, K Hoffmann, R Hussain, ...
Medical Physics 31 (6), 1826-1827, 2004
52004
The system can't perform the operation now. Try again later.
Articles 1–20