Follow
Guang-Hong Chen
Guang-Hong Chen
Charles A. Mistretta Professor of Medical Physics and Radiology, University of Wisconsin-Madison
Verified email at wisc.edu
Title
Cited by
Cited by
Year
Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
GH Chen, J Tang, S Leng
Medical physics 35 (2), 660-663, 2008
13132008
Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging
PJ Pickhardt, MG Lubner, DH Kim, J Tang, JA Ruma, AM del Rio, ...
American journal of roentgenology 199 (6), 1266-1274, 2012
3822012
Performance comparison between total variation (TV)-based compressed sensing and statistical iterative reconstruction algorithms
J Tang, BE Nett, GH Chen
Physics in Medicine & Biology 54 (19), 5781, 2009
3592009
Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT
CH McCollough, GH Chen, W Kalender, S Leng, E Samei, K Taguchi, ...
Radiology 264 (2), 567-580, 2012
3282012
Accuracy of liver fat quantification with advanced CT, MRI, and ultrasound techniques: prospective comparison with MR spectroscopy
H Kramer, PJ Pickhardt, MA Kliewer, D Hernando, GH Chen, ...
American journal of Roentgenology 208 (1), 92-100, 2017
2282017
High temporal resolution and streak-free four-dimensional cone-beam computed tomography
S Leng, J Tang, J Zambelli, B Nett, R Tolakanahalli, GH Chen
Physics in medicine & biology 53 (20), 5653, 2008
1972008
Learning to reconstruct computed tomography images directly from sinogram data under a variety of data acquisition conditions
Y Li, K Li, C Zhang, J Montoya, GH Chen
IEEE transactions on medical imaging 38 (10), 2469-2481, 2019
1592019
Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data
T Zhuang, S Leng, BE Nett, GH Chen
Physics in Medicine & Biology 49 (24), 5489, 2004
1492004
Statistical model based iterative reconstruction (MBIR) in clinical CT systems: experimental assessment of noise performance
K Li, J Tang, GH Chen
Medical physics 41 (4), 041906, 2014
1452014
Streaking artifacts reduction in four‐dimensional cone‐beam computed tomography
S Leng, J Zambelli, R Tolakanahalli, B Nett, P Munro, J Star‐Lack, ...
Medical physics 35 (10), 4649-4659, 2008
1432008
Exchange-induced enhancement of spin-orbit coupling in two-dimensional electronic systems
GH Chen, ME Raikh
Physical Review B 60 (7), 4826, 1999
1401999
Diagnosis of coronavirus disease 2019 pneumonia by using chest radiography: Value of artificial intelligence
R Zhang, X Tie, Z Qi, NB Bevins, C Zhang, D Griner, TK Song, JD Nadig, ...
Radiology 298 (2), E88-E97, 2021
1362021
Prior image constrained compressed sensing: Implementation and performance evaluation
PT Lauzier, J Tang, GH Chen
Medical physics 39 (1), 66-80, 2012
1342012
Quantitative imaging of electron density and effective atomic number using phase contrast CT
Z Qi, J Zambelli, N Bevins, GH Chen
Physics in Medicine & Biology 55 (9), 2669, 2010
1272010
Multicontrast x‐ray computed tomography imaging using Talbot‐Lau interferometry without phase stepping
N Bevins, J Zambelli, K Li, Z Qi, GH Chen
Medical physics 39 (1), 424-428, 2012
1242012
Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing
TP Szczykutowicz, GH Chen
Physics in Medicine & Biology 55 (21), 6411, 2010
1242010
Temporal resolution improvement using PICCS in MDCT cardiac imaging
GH Chen, J Tang, J Hsieh
Medical physics 36 (6Part1), 2130-2135, 2009
1132009
Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance
K Li, J Garrett, Y Ge, GH Chen
Medical physics 41 (7), 071911, 2014
1002014
Time-resolved interventional cardiac C-arm cone-beam CT: An application of the PICCS algorithm
GH Chen, P Thériault-Lauzier, J Tang, B Nett, S Leng, J Zambelli, Z Qi, ...
IEEE transactions on medical imaging 31 (4), 907-923, 2011
932011
Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm
MG Lubner, PJ Pickhardt, J Tang, GH Chen
Radiology 260 (1), 248-256, 2011
922011
The system can't perform the operation now. Try again later.
Articles 1–20