Luke Bisby, Professor of Fire & Structures
Luke Bisby, Professor of Fire & Structures
School of Engineering, University of Edinburgh, UK
Verified email at ed.ac.uk - Homepage
Title
Cited by
Cited by
Year
Response to fire of concrete structures that incorporate FRP
LA Bisby, MF Green, VKR Kodur
Progress in Structural Engineering and Materials 7 (3), 136-149, 2005
1642005
Comparison of confinement models for FRP wrapped concrete
LA Bisby, AJ Dent, MF Green
ACI Structural Journal, 62-72, 2005
1572005
Effect of freeze-thaw cycles on the bond durability between fibre reinforced polymer plate reinforcement and concrete
MF Green, LA Bisby, Y Beaudoin, P Labossière
Canadian journal of civil engineering 27 (5), 949-959, 2000
1502000
Fire endurance of fiber-reinforced polymer strengthened concrete T-beams
B Williams, V Kodur, MF Green, L Bisby
ACI structural Journal 105 (1), 60, 2008
1332008
Axial–flexural interaction in circular FRP-confined reinforced concrete columns
L Bisby, M Ranger
Construction and Building Materials 24 (9), 1672-1681, 2010
1202010
Fire behaviour of fibre-reinforced polymer (FRP) reinforced or confined concrete
LA Bisby
Queen's University, 2003
1202003
Slenderness effects on circular CFRP confined reinforced concrete columns
J Fitzwilliam, LA Bisby
Journal of Composites for Construction 14 (3), 280-288, 2010
1142010
Fire insulation schemes for FRP-strengthened concrete slabs
B Williams, L Bisby, V Kodur, M Green, E Chowdhury
Composites Part A: Applied Science and Manufacturing 37 (8), 1151-1160, 2006
1072006
FRP confined concrete columns: Behaviour under extreme conditions
MF Green, LA Bisby, AZ Fam, VKR Kodur
Cement and concrete composites 28 (10), 928-937, 2006
1012006
Fire endurance of fiber-reinforced polymer-confined concrete
LA Bisby, VR Kodur, MF Green
ACI Structural Journal 102 (6), 883-891, 2005
1002005
A contemporary review of large-scale non-standard structural fire testing
L Bisby, J Gales, C Maluk
Fire science reviews 2 (1), 1, 2013
982013
Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire
LA Bisby, MF Green, VKR Kodur
Journal of Composites for Construction 9 (1), 15-24, 2005
932005
Investigation of insulated FRP-wrapped reinforced concrete columns in fire
EU Chowdhury, LA Bisby, MF Green, VKR Kodur
Fire Safety Journal 42 (6-7), 452-460, 2007
912007
Evaluation of fire endurance of concrete slabs reinforced with fiber-reinforced polymer bars
VKR Kodur, LA Bisby
Journal of structural engineering 131 (1), 34-43, 2005
852005
Experimental review of the homogeneous temperature assumption in post-flashover compartment fires
J Stern-Gottfried, G Rein, LA Bisby, JL Torero
Fire Safety Journal 45 (4), 249-261, 2010
812010
Experimental evaluation of the fire behaviour of insulated fibre-reinforced-polymer-strengthened reinforced concrete columns
VKR Kodur, LA Bisby, MF Green
Fire safety journal 41 (7), 547-557, 2006
812006
Fire behaviour of FRP-strengthened reinforced concrete structural elements: A state-of-the-art review
JP Firmo, JR Correia, LA Bisby
Composites Part B: Engineering 80, 198-216, 2015
782015
Mechanical characterization of fibre reinforced polymers materials at high temperature
EU Chowdhury, R Eedson, LA Bisby, MF Green, N Benichou
Fire technology 47 (4), 1063-1080, 2011
772011
Effects of elevated temperature on near surface mounted and externally bonded FRP strengthening systems for concrete
PJ Burke, LA Bisby, MF Green
Cement and Concrete Composites 35 (1), 190-199, 2013
752013
Preliminary guidance for the design of FRP-strengthened concrete members exposed to fire
VKR Kodur, LA Bisby, MF Green
Journal of Fire Protection Engineering 17 (1), 5-26, 2007
752007
The system can't perform the operation now. Try again later.
Articles 1–20