Liver segmentation: indications, techniques and future directions A Gotra, L Sivakumaran, G Chartrand, KN Vu, F Vandenbroucke-Menu, ... Insights into imaging 8, 377-392, 2017 | 211 | 2017 |
Evaluating disease progression using magnetic resonance imaging JP Pelletier, J Pelletier, MJ de Guise, JP Raynauld, MJ Barthiaume, ... US Patent 6,560,476, 2003 | 187 | 2003 |
Reliability of a quantification imaging system using magnetic resonance images to measure cartilage thickness and volume in human normal and osteoarthritic knees JP Raynauld, C Kauffmann, G Beaudoin, MJ Berthiaume, JA de Guise, ... Osteoarthritis and cartilage 11 (5), 351-360, 2003 | 187 | 2003 |
Computer-aided method for quantification of cartilage thickness and volume changes using MRI: validation study using a synthetic model C Kauffmann, P Gravel, B Godbout, A Gravel, G Beaudoin, JP Raynauld, ... IEEE transactions on Biomedical Engineering 50 (8), 978-988, 2003 | 177 | 2003 |
Noninvasive quantitation of human liver steatosis using magnetic resonance and bioassay methods G d’Assignies, M Ruel, A Khiat, L Lepanto, M Chagnon, C Kauffmann, ... European radiology 19, 2033-2040, 2009 | 128 | 2009 |
Measurements and detection of abdominal aortic aneurysm growth: accuracy and reproducibility of a segmentation software C Kauffmann, A Tang, É Therasse, MF Giroux, S Elkouri, P Melanson, ... European journal of radiology 81 (8), 1688-1694, 2012 | 104 | 2012 |
Fatty liver deposition and sparing: a pictorial review PO Décarie, L Lepanto, JS Billiard, D Olivié, J Murphy-Lavallée, ... Insights into imaging 2, 533-538, 2011 | 101 | 2011 |
On the texture bias for few-shot cnn segmentation R Azad, AR Fayjie, C Kauffmann, I Ben Ayed, M Pedersoli, J Dolz Proceedings of the IEEE/CVF winter conference on applications of computer …, 2021 | 94 | 2021 |
Semi-supervised few-shot learning for medical image segmentation AR Feyjie, R Azad, M Pedersoli, C Kauffman, IB Ayed, J Dolz arXiv preprint arXiv:2003.08462, 2020 | 87 | 2020 |
Analysis of pressure distribution at the body–seat interface in able-bodied and paraplegic subjects using a deformable active contour algorithm R Aissaoui, C Kauffmann, J Dansereau, JA de Guise Medical engineering & physics 23 (6), 359-367, 2001 | 85 | 2001 |
Seeded ND medical image segmentation by cellular automaton on GPU C Kauffmann, N Piché International journal of computer assisted radiology and surgery 5, 251-262, 2010 | 78 | 2010 |
Rupture signs on computed tomography, treatment, and outcome of abdominal aortic aneurysms KN Vu, Y Kaitoukov, F Morin-Roy, C Kauffmann, MF Giroux, É Thérasse, ... Insights into Imaging 5, 281-293, 2014 | 69 | 2014 |
Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm C Kauffmann, F Douane, E Therasse, S Lessard, S Elkouri, P Gilbert, ... Journal of Vascular and Interventional Radiology 26 (4), 544-551, 2015 | 60 | 2015 |
Clinical validation of a software for quantitative follow-up of abdominal aortic aneurysm maximal diameter and growth by CT angiography C Kauffmann, A Tang, A Dugas, É Therasse, V Oliva, G Soulez European journal of radiology 77 (3), 502-508, 2011 | 59 | 2011 |
A literature review of the numerical analysis of abdominal aortic aneurysms treated with endovascular stent grafts D Roy, C Kauffmann, S Delorme, S Lerouge, G Cloutier, G Soulez Computational and mathematical methods in medicine 2012 (1), 820389, 2012 | 49 | 2012 |
Cellular automaton for ultra-fast watershed transform on GPU C Kauffmann, N Piche 2008 19th International Conference on Pattern Recognition, 1-4, 2008 | 47 | 2008 |
Reproducibility of abdominal aortic aneurysm diameter measurement and growth evaluation on axial and multiplanar computed tomography reformations A Dugas, É Therasse, C Kauffmann, A Tang, S Elkouri, A Nozza, ... Cardiovascular and interventional radiology 35, 779-787, 2012 | 46 | 2012 |
Outcomes of venous malformation sclerotherapy: a review of study methodology and long-term results S Ali, SE Mitchell Seminars in Interventional Radiology 34 (03), 288-293, 2017 | 44 | 2017 |
Finite element analysis of abdominal aortic aneurysms: geometrical and structural reconstruction with application of an anisotropic material model D Roy, GA Holzapfel, C Kauffmann, G Soulez The IMA Journal of Applied Mathematics 79 (5), 1011-1026, 2014 | 43 | 2014 |
Flow stagnation volume and abdominal aortic aneurysm growth: Insights from patient-specific computational flow dynamics of Lagrangian-coherent structures F Joly, G Soulez, D Garcia, S Lessard, C Kauffmann Computers in biology and medicine 92, 98-109, 2018 | 41 | 2018 |