Follow
Peter Luscuere
Peter Luscuere
Hoogleraar Building Services, Faculteit Bouwkunde, TU Delft
Verified email at tudelft.nl
Title
Cited by
Cited by
Year
An exergy application for analysis of buildings and HVAC systems
P Sakulpipatsin, LCM Itard, HJ Van der Kooi, EC Boelman, PG Luscuere
Energy and buildings 42 (1), 90-99, 2010
1642010
Bringing nature to work: Preferences and perceptions of constructed indoor and natural outdoor workspaces
G Mangone, CA Capaldi, ZM Van Allen, PG Luscuere
Urban forestry & urban greening 23, 1-12, 2017
682017
Constructing thermal comfort: Investigating the effect of vegetation on indoor thermal comfort through a four season thermal comfort quasi-experiment
G Mangone, SR Kurvers, PG Luscuere
Building and Environment 81, 410-426, 2014
602014
The exergy approach for evaluating and developing an energy system for a social dwelling
SC Jansen, J Terés-Zubiaga, PG Luscuere
Energy and Buildings 55, 693-703, 2012
382012
Circular and flexible infill concepts: Integration of the residential user perspective
B Geldermans, M Tenpierik, P Luscuere
Sustainability 11 (1), 261, 2019
312019
Circular and flexible indoor partitioning—a design conceptualization of innovative materials and value chains
B Geldermans, M Tenpierik, P Luscuere
Buildings 9 (9), 194, 2019
242019
Dynamic exergy analysis of energy systems for a social dwelling and exergy based system improvement
J Terés-Zubiaga, SC Jansen, P Luscuere, JM Sala
Energy and Buildings 64, 359-371, 2013
242013
Possibilities and limitations of CFD simulation for indoor climate analysis
JP Den Hartog, A Koutamanis, PG Luscuere
Fifth Design and Decision Support Systems in Architecture and Urban Planning …, 2000
242000
An architect friendly interface for a dynamic building simulation program
E Van Dijk, P Luscuere
Sustainable Building, 2002
212002
Simulation and evaluation of environmental aspects throughout the design process
JP Hartog, A Koutamanis, PG Luscuere
4th Design and Decision Support Systems in Architecture and Urban Planning …, 1998
121998
Operating room ventilation systems: recovery degree, cleanliness recovery rate and air change effectiveness in an ultra-clean area
JLA Lans, NMC Mathijssen, A Bode, JJ van den Dobbelsteen, ...
Journal of Hospital Infection 122, 115-125, 2022
112022
Human health and well-being in relation to circular and flexible infill design: assessment criteria on the operational level
B Geldermans, M Tenpierik, P Luscuere
Sustainability 11 (7), 1984, 2019
102019
Functional exergy efficiency and exergy consumption behaviour for air-to-air heat exchangers operating at near-environmental temperatures
EC Boelman, P Sakulpipatsin, HJ Van Der Kooi, LCM Itard, PG Luscuere
International Journal of Exergy 5 (5-6), 582-604, 2008
102008
Airconditioning in nursing homes till death do us part
PG Luscuere, V Borst
Proceeding of the 9th international conference on indoor air quality and …, 2002
102002
Indoor air quality in hospitals and other health care facilities
J McCarthy, P Luscuere, A Streifel, P Kalliokoski
Proceeding of Healthy Buildings, 2000
82000
Functional exergy efficiency at near-environmental temperatures
EC Boelman, P Sakulpipatsin, HJ Van der Kooi, LCM Itard, PG Luscuere
ASHRAE Transactions 115 (2), 748-760, 2009
72009
Evaluation of computer flow modelling in operating theatres
AD Lemaire, PJ Ham, PG Luscuere
13th International Symposium on Contamination Control, Nederlands …, 1996
71996
Improvement capabilities of operating theatres with the help of computer flow modeling
P Luscuere, T Lemaire, PJ Ham
Indoor Air'93, 575-580, 1993
71993
Spatial decision support systems for hospital layout design: A review
Z Jia, P Nourian, P Luscuere, C Wagenaar
Journal of Building Engineering 67, 106042, 2023
62023
A reference environment for the calculation of the exergy value of air in buildings
P Sakulpipatsin, LCM Itard, HJ Van Der Kooi, PG Luscuere, EC Boelman
ASHRAE Transactions 115 (1), 10-16, 2009
62009
The system can't perform the operation now. Try again later.