François DeBlois
François DeBlois
Assistant Professor, McGill University
Verified email at mcgill.ca
TitleCited byYear
SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes
G Poludniowski, G Landry, F DeBlois, PM Evans, F Verhaegen
Physics in Medicine & Biology 54 (19), N433, 2009
5062009
Radiation physics for medical physicists
EB Podgoršak
Springer, 2006
4722006
Calculation of x‐ray spectra emerging from an x‐ray tube. Part I. Electron penetration characteristics in x‐ray targets
GG Poludniowski, PM Evans
Medical physics 34 (6Part1), 2164-2174, 2007
1902007
Absorption spectra time evolution of EBT‐2 model GAFCHROMIC™ film
S Devic, S Aldelaijan, H Mohammed, N Tomic, LH Liang, F DeBlois, ...
Medical physics 37 (5), 2207-2214, 2010
1052010
Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays
F Verhaegen, B Reniers, F Deblois, S Devic, J Seuntjens, D Hristov
Physics in Medicine & Biology 50 (15), 3555, 2005
912005
Validation of Monte Carlo calculated surface doses for megavoltage photon beams
W Abdel‐Rahman, JP Seuntjens, F Verhaegen, F Deblois, EB Podgorsak
Medical physics 32 (1), 286-298, 2005
702005
Linearization of dose–response curve of the radiochromic film dosimetry system
S Devic, N Tomic, S Aldelaijan, F DeBlois, J Seuntjens, MF Chan, D Lewis
Medical physics 39 (8), 4850-4857, 2012
582012
Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition
N Tomic, S Devic, F DeBlois, J Seuntjens
Medical physics 37 (3), 1083-1092, 2010
582010
Improving the energy response of external beam therapy (EBT) GafChromicTM dosimetry films at low energies (≤100 keV)
H Bekerat, S Devic, F DeBlois, K Singh, A Sarfehnia, J Seuntjens, S Shih, ...
Medical physics 41 (2), 022101, 2014
572014
Evaluation of EBT‐2 model GAFCHROMIC™ film performance in water
S Aldelaijan, S Devic, H Mohammed, N Tomic, LH Liang, F DeBlois, ...
Medical physics 37 (7Part1), 3687-3693, 2010
532010
Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams
R Doucet, M Olivares, F DeBlois, EB Podgorsak, I Kawrakow, J Seuntjens
Physics in Medicine & Biology 48 (15), 2339, 2003
472003
Radiochromic film dosimetry of HDR 192Ir source radiation fields
S Aldelaijan, H Mohammed, N Tomic, LH Liang, F DeBlois, A Sarfehnia, ...
Medical physics 38 (11), 6074-6083, 2011
462011
MMCTP: a radiotherapy research environment for Monte Carlo and patient-specific treatment planning
A Alexander, F DeBlois, G Stroian, K Al-Yahya, E Heath, J Seuntjens
Physics in Medicine & Biology 52 (13), N297, 2007
432007
Saturation current and collection efficiency for ionization chambers in pulsed beams
F DeBlois, C Zankowski, EB Podgorsak
Medical physics 27 (5), 1146-1155, 2000
412000
Characterization of calibration curves and energy dependence GafChromicTM XR‐QA2 model based radiochromic film dosimetry system
N Tomic, C Quintero, BR Whiting, S Aldelaijan, H Bekerat, LH Liang, ...
Medical physics 41 (6Part1), 062105, 2014
332014
Stereotactic fractionated radiotherapy in the treatment of juxtapapillary choroidal melanoma: the McGill University experience
R Al-Wassia, A Dal Pra, K Shun, A Shaban, C Corriveau, C Edelstein, ...
International Journal of Radiation Oncology* Biology* Physics 81 (4), e455-e462, 2011
262011
Sorafenib in combination with ionizing radiation has a greater anti-tumour activity in a breast cancer model
M Heravi, N Tomic, LH Liang, S Devic, J Holmes, F Deblois, D Radzioch, ...
Anti-cancer drugs 23 (5), 525-533, 2012
192012
Toward automatic field selection and planning using Monte Carlo-based direct aperture optimization in modulated electron radiotherapy
A Alexander, F DeBlois, J Seuntjens
Physics in Medicine & Biology 55 (16), 4563, 2010
182010
Reference dosimetry during diagnostic CT examination using XR‐QA radiochromic film model
J Boivin, N Tomic, B Fadlallah, F DeBlois, S Devic
Medical physics 38 (9), 5119-5129, 2011
162011
ImaSim, a software tool for basic education of medical X-ray imaging in radiotherapy and radiology
F Verhaegen
Frontiers in Physics 1, 22, 2013
132013
The system can't perform the operation now. Try again later.
Articles 1–20