Follow
Zhengguo Tan
Title
Cited by
Cited by
Year
Model‐based T1 mapping with sparsity constraints using single‐shot inversion‐recovery radial FLASH
X Wang, V Roeloffs, J Klosowski, Z Tan, D Voit, M Uecker, J Frahm
Magnetic resonance in medicine 79 (2), 730-740, 2018
1032018
Magnetic resonance imaging of noradrenergic neurons
T Watanabe, Z Tan, X Wang, A Martinez-Hernandez, J Frahm
Brain Structure and Function 224, 1609-1625, 2019
652019
Advances in real‐time phase‐contrast flow MRI using asymmetric radial gradient echoes
M Untenberger, Z Tan, D Voit, AA Joseph, V Roeloffs, KD Merboldt, ...
Magnetic resonance in medicine 75 (5), 1901-1908, 2016
652016
Cation location and migration in lanthanum-exchanged NaY zeolite
X Du, H Zhang, X Li, Z Tan, H Liu, X Gao
Chinese Journal of Catalysis 34 (8), 1599-1607, 2013
502013
Model‐based reconstruction for real‐time phase‐contrast flow MRI: improved spatiotemporal accuracy
Z Tan, V Roeloffs, D Voit, AA Joseph, M Untenberger, KD Merboldt, ...
Magnetic resonance in medicine 77 (3), 1082-1093, 2017
472017
Physics-based reconstruction methods for magnetic resonance imaging
X Wang, Z Tan, N Scholand, V Roeloffs, M Uecker
Philosophical Transactions of the Royal Society A 379 (2200), 20200196, 2021
302021
Magnetic resonance imaging of brain cell water
T Watanabe, X Wang, Z Tan, J Frahm
Scientific Reports 9 (1), 5084, 2019
272019
mrirecon/bart: version 0.7. 00
M Uecker, C Holme, M Blumenthal, X Wang, Z Tan, N Scholand, S Iyer, ...
Zenodo doi 10, 2021
252021
Dynamic water/fat separation and inhomogeneity mapping—joint estimation using undersampled triple‐echo multi‐spoke radial FLASH
Z Tan, D Voit, JM Kollmeier, M Uecker, J Frahm
Magnetic Resonance in Medicine 82 (3), 1000-1011, 2019
202019
An eigenvalue approach for the automatic scaling of unknowns in model‐based reconstructions: Application to real‐time phase‐contrast flow MRI
Z Tan, T Hohage, O Kalentev, AA Joseph, X Wang, D Voit, KD Merboldt, ...
NMR in Biomedicine 30 (12), e3835, 2017
182017
Carotid artery flow as determined by real-time phase-contrast flow MRI and neurovascular ultrasound: A comparative study of healthy subjects
IL Maier, S Hofer, AA Joseph, KD Merboldt, Z Tan, K Schregel, M Knauth, ...
European journal of radiology 106, 38-45, 2018
152018
MARTINI and GRAPPA - When speed is taste
T Hilbert, T Kober, TJ Sumpf, Z Tan, J Frahm, P Falkovskiy, H Meyer, ...
Proc. Intl. Soc. Mag. Reson. Med. 22, 4077, 2014
92014
Real‐time multi‐directional flow MRI using model‐based reconstructions of undersampled radial FLASH–A feasibility study
JM Kollmeier, Z Tan, AA Joseph, O Kalentev, D Voit, KD Merboldt, ...
NMR in Biomedicine 32 (12), e4184, 2019
72019
Free‐breathing myocardial T1 mapping using inversion‐recovery radial FLASH and motion‐resolved model‐based reconstruction
X Wang, S Rosenzweig, V Roeloffs, M Blumenthal, N Scholand, Z Tan, ...
Magnetic Resonance in Medicine 89 (4), 1368-1384, 2023
52023
Joint estimation of coil sensitivities and image content using a deep image prior
G Luo, X Wang, V Roeloffs, Z Tan, M Uecker
Proceedings of the 29th Annual Meeting of ISMRM, 280, 2021
52021
Diffusion‐weighted MRI of the prostate without susceptibility artifacts: Undersampled multi‐shot turbo‐STEAM with rotated radial trajectories
A Merrem, S Hofer, A Seif Amir Hosseini, D Voit, KD Merboldt, Z Tan, ...
NMR in Biomedicine 32 (5), e4074, 2019
42019
Advances in real-time phase-contrast flow MRI and multi-echo radial FLASH
Z Tan
Niedersächsische Staats-und Universitätsbibliothek Göttingen, 2016
42016
Free-Breathing Liver Fat, R*2 and B0 Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-based Reconstruction
Z Tan, C Unterberg-Buchwald, M Blumenthal, N Scholand, P Schaten, ...
IEEE Transactions on Medical Imaging, 2022
22022
SU‐E‐I‐77: X‐Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4
A Kapadia, E Samei, B Harrawood, P Sahbaee, A Chawla, Z Tan, D Brady
Medical Physics 39 (6Part5), 3642-3643, 2012
12012
Application of k-space energy spectrum analysis to artifact correction in PROPELLER EPI
Z Tan, N Chen
Proc. Intl. Soc. Mag. Reson. Med. 20, 2422, 2012
12012
The system can't perform the operation now. Try again later.
Articles 1–20