Follow
SHUAI LENG
Title
Cited by
Cited by
Year
Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
GH Chen, J Tang, S Leng
Medical physics 35 (2), 660-663, 2008
12222008
Dual-and multi-energy CT: principles, technical approaches, and clinical applications
CH McCollough, S Leng, L Yu, JG Fletcher
Radiology 276 (3), 637, 2015
10632015
Dual-energy CT–based monochromatic imaging
L Yu, S Leng, CH McCollough
American journal of Roentgenology 199 (5_supplement), S9-S15, 2012
5572012
CT dose index and patient dose: they are not the same thing
CH McCollough, S Leng, L Yu, DD Cody, JM Boone, MF McNitt-Gray
Radiology 259 (2), 311, 2011
4952011
Radiation dose reduction in computed tomography: techniques and future perspective
L Yu, X Liu, S Leng, JM Kofler, JC Ramirez-Giraldo, M Qu, J Christner, ...
Imaging in medicine 1 (1), 65, 2009
3892009
Virtual monochromatic imaging in dual‐source dual‐energy CT: radiation dose and image quality
L Yu, JA Christner, S Leng, J Wang, JG Fletcher, CH McCollough
Medical physics 38 (12), 6371-6379, 2011
3072011
Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT
CH McCollough, GH Chen, W Kalender, S Leng, E Samei, K Taguchi, ...
Radiology 264 (2), 567, 2012
3032012
Identification of intraarticular and periarticular uric acid crystals with dual-energy CT: initial evaluation
KN Glazebrook, LS Guimar„es, NS Murthy, DF Black, T Bongartz, ...
Radiology 261 (2), 516-524, 2011
2692011
Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study
T Bongartz, KN Glazebrook, SJ Kavros, NS Murthy, SP Merry, WB Franz, ...
Annals of the rheumatic diseases 74 (6), 1072-1077, 2015
2592015
Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Z Yu, S Leng, SM Jorgensen, Z Li, R Gutjahr, B Chen, AF Halaweish, ...
Physics in Medicine & Biology 61 (4), 1572, 2016
1952016
High temporal resolution and streak-free four-dimensional cone-beam computed tomography
S Leng, J Tang, J Zambelli, B Nett, R Tolakanahalli, GH Chen
Physics in medicine & biology 53 (20), 5653, 2008
1902008
Dual‐source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality
TG Flohr, S Leng, L Yu, T Allmendinger, H Bruder, M Petersilka, ...
Medical physics 36 (12), 5641-5653, 2009
1842009
Human imaging with photon-counting-based CT at clinical dose levels: Contrast-to-noise ratio and cadaver studies
R Gutjahr, AF Halaweish, Z Yu, S Leng, L Yu, Z Li, SM Jorgensen, ...
Investigative radiology 51 (7), 421, 2016
1752016
Prevalence of extracoronary vascular abnormalities and fibromuscular dysplasia in patients with spontaneous coronary artery dissection
M Prasad, MS Tweet, SN Hayes, S Leng, JJ Liang, MF Eleid, R Gulati, ...
The American journal of cardiology 115 (12), 1672-1677, 2015
1622015
Photon-counting detector CT: system design and clinical applications of an emerging technology
S Leng, M Bruesewitz, S Tao, K Rajendran, AF Halaweish, NG Campeau, ...
Radiographics 39 (3), 729, 2019
1542019
Three-dimensional physical modeling: applications and experience at Mayo Clinic
JS Matsumoto, JM Morris, TA Foley, EE Williamson, S Leng, KP McGee, ...
Radiographics 35 (7), 1989-2006, 2015
1442015
Prediction of human observer performance in a 2‐alternative forced choice low‐contrast detection task using channelized Hotelling observer: Impact of radiation dose and†…
L Yu, S Leng, L Chen, JM Kofler, RE Carter, CH McCollough
Medical physics 40 (4), 041908, 2013
1442013
Dual-energy dual-source CT with additional spectral filtration can improve the differentiation of non-uric acid renal stones: an ex vivo phantom study
M Qu, JCR Giraldo, S Leng, JC Williams, TJ Vrtiska, JC Lieske, ...
AJR. American journal of roentgenology 196 (6), 1279, 2011
1422011
Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data
T Zhuang, S Leng, BE Nett, GH Chen
Physics in Medicine & Biology 49 (24), 5489, 2004
1422004
Bismuth shielding, organ-based tube current modulation, and global reduction of tube current for dose reduction to the eye at head CT
J Wang, X Duan, JA Christner, S Leng, KL Grant, CH McCollough
Radiology 262 (1), 191-198, 2012
1382012
The system can't perform the operation now. Try again later.
Articles 1–20